![ADTRAN DS3-PSM Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/adtran/ds3-psm/ds3-psm_installation-and-maintenance-practice_2855151116.webp)
Total Access 3000 DSLAM DS3 Primary Switch Module Installation and Maintenance Practice
106
61181041L3-5A
Table 63. Single Card Cell Generation Test Menu Options
Option
Description
Function
1
Shelf 1, Slot 1
This option is used to input the shelf/slot number.
2
Configuration
This option is used to select a configuration. The options are
as follows:
• Single Port Loopback: Each port of the access module
being tested must be manually put in loopback. When
this test is initiated the DS3-PSM creates a temporary
PVC for each port on the access module and starts
generating cells on those PVCs.
• Daisy Chain: This test creates multiple temporary PVCs
that send the test pattern from the first port, through
each port, to the last port and back again. The cells are
checked and counted on each end and in both
directions.
For this test, adjacent ports on the access modules
must be connected to each other. For example, on a 4-
port access module, ports 1 and 2 should be connected
to each other and ports 3 and 4 should be connected to
each other.
3
Start New Test
This option is used to start a new test which displays
statistics in real time. After this option is selected, the text
dynamically changes to “stop test” and the options below are
available.
4
Reset Counters
This option is used to reset the counters during a test.
5
Insert CRC Error
This option is used to insert CRC errors during a test.