6
PRELIMINARY
Issue 1, Au
gust 2003
6
1225
236
L1-5A
Figure 3. SHDSL T1/E1 NTU Menu Tree
1. Unit Information
Main
Menu
SHDSL Version
Vendor List Number
Vendor Issue Number
Vendor Software Version
Unit Identification Code (CLEI)
Vendor ID
Vendor Model Number
Vendor Serial Number
Manufacture Date
PROM Check Sum
2. Provisioning
3. Status
4. Test
1. Data Mode = T1/E1, Timeslots
2. Local Management = Enabled
3. Restore Factory Defaults
4. Upgrade Firmware
5. Change Password
1. Line Coding = HDB3*
2. Framing Mode = CCS*
3. ISDN-PRA V3 = Disabled*
4. Idle Pattern = FFh*
1. DS1 Tx Level
2. Line Coding*
3. Framing Mode*
4. Idle Pattern*
5. FDL Monitoring*
1. Dual Sided
2. Customer
3. Network
4. Off
1. Local Loopback
2. Remote Loopback
3. BERT
1. SHDSL = ALARMS
2. E1 = ALARMS
1. LTU
2. NTU
1. SHDSL
2. E1
1. SES Count Threshold = 50 CVCs
2. SNR Margin Alarm Threshold = Disabled
3. Loop Attenuation Alarm Threshold = Disabled
4. ES 15 Minute Alarm Threshold = Disabled
5. Performance History
6. Terminal Mode
1. Unit Options
2. SHDSL Options
3.
4. Test Options
General Status
Aggregate Rate (kbps)
SNR Margin (dB) (Cur/Min/Max)
Loop Attenuation (dB) (Cur/Min/Max)
Errored Seconds (ES)
Severely Errored Seconds (SES)
Unavailable Seconds (UAS)
Code Violations Count (CVC)
LOSW Seconds (LOSWS)
Loopback Status
BERT Status
General Status
Data Rate
Framing Mode
Errored Seconds (ES)
Severely Errored Seconds (SES)
Unavailable Seconds (UAS)
Code Violations Count (CVC)
Transmit Network Alarm Indication Signal (Tx Net AIS)
Transmit Customer Alarm Indication Signal (Tx Cust AIS)
Network Source Address Bits (Net SAS-Bits)
Customer Source Address Bits (Cust SA -Bits)
Network Address Bit (Cust A-Bit)
SHDSL Version
Vendor List Number
Vendor Issue Number
Vendor Software Version
Unit Identification Code (CLEI)
Vendor ID
Vendor Model Number
Vendor Serial Number
Other Vendor Information
1. Loopback Time Out = Disabled
2. BERT Pattern = 2e15-1
3. BERT Pattern Polarity = Normal
1. Data Type = E1
2. Data Rate = 3
3. Apply Settings
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Normal
2. Inverted
1. ALT
2. 2047
3. 2e15-1
4. QRSS
1. 0 db
2. -7.5 db
3. -15 db
0. Disabled
1-15. Threshold in dB
0. Disabled
1-127. Threshold in dB
0. Disabled
1-900. Seconds
1. E1 Options
2. T1 Options
0. Disabled
1-999. Timeout in Minutes
1. AMI
2. HDB3
1. AMI
2. B8ZS
1. Unframed
2. CCS
3. CCS w/CRCA
1. Unframed
2. SF
3. ESF
0. Disabled
1-65535. Errors
1.-255. CVCs to cause a SES
5. SES 15 Minute Alarm Threshold = Disabled
6. UAS 15 Minute Alarm Threshold = Disabled
7. CVC 15 Minute Alarm Threshold = Disabled
8. LOSWS 15 Minute Alarm Threshold = Disabled
* Option must be changed by the LTU
Содержание 1225236L1