Table 4. Configuration Options List
Category
Option
Setting
Default
Unit Options
Data Mode
For Data Type = T1, Data Rate can
be from 3 to 24 time slots
(i.e. 200 kbps to 1.544 Mbps)
For Data Type = E1, Data Rate can
be from 3 to 32 time slots
(i.e., 192 kbps to 2.048 Mbps)
Data Type = T1
Data Rate = 24
Local Management
1 = Disabled
2 = Enabled
Enabled
Restore Factory Defaults
Firmware Upgrade
Change Password
SHDSL Options
SES CVC Threshold
0 to 255 CVC’s
50
SNR Margin Alarm
Threshold
0 = Disabled
1 to 15db = Alarm Threshold
Disabled
Loop Attenuation Alarm
Threshold
0 = Disabled
1 to 127db = Alarm Threshold
Disabled
ES 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
Disabled
SES 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
Disabled
UAS 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
Disabled
CVC 15 Minute Alarm
Threshold
0 = Disabled
1 to 65535 Errors = Alarm threshold
Disabled
LOSWS 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 Seconds = Alarm Threshold
Disabled
T1 Options (T1 Mode Only)
Line Coding
1 = AMI
2 = B8ZS
B8ZS
Framing Mode
1 = Unframed
2 = SF
3 = ESF
ESF
Idle Pattern
00h to FFh
7Fh
FDL Monitoring (ESF Mode
Only)
1 = Disabled
2 = Enabled
Disabled