background image

2    

Issue 1, August 2003

61225236L1-5A

Features

The features of the SHDSL T1/E1 NTU, P/N 
1225236L1, include the following:

• Responds to an Embedded Operations Channel 

(EOC) inventory response message

• Timing source is derived from the received SHDSL 

network signal

• Local management access via VT100 menus 
• Remote management access via EOC message
• Operates in T1 mode with a data rate of 200 kbps   

to 1.544 Mbps and E1 mode with a data rate of     
192 kbps to 2.048 Mbps

• Non-volatile memory configuration
• Factory default restoration via VT100 menu screens 

or EOC messages

• Firmware upgrade using local management port or 

remotely via EOC messages

• Password protection for local management access 

and firmware upgrade

See 

Figure 2

 for a typical configuration setup.

Compliance

Table 1

 shows the compliance codes for the SHDSL T1/

E1 NTU. The SHDSL T1/E1 NTU is NRTL listed to the 
applicable UL standards. The SHDSL T1/E1 NTU is to 
be installed in a restricted access location and in a Type 
“B” or “E” enclosure only. 

This device complies with Part 15 of the FCC rules. 
Operation is subject to the following two conditions: 

1. This device may not cause harmful interference.

2. This device must accept any interference received, 

including interference that may cause undesired 
operation.

Changes or modifications not expressly approved by 
ADTRAN could void the user’s authority to operate this 
equipment.

3. INSTALLATION

After unpacking the SHDSL T1/E1 NTU, inspect it for 
damage. If damage has occurred, file a claim with the 
carrier, then contact ADTRAN Customer Service. 
Refer to the 

Warranty and Customer Service

 

section for 

further information. If possible, keep the original 
shipping container for returning the SHDSL T1/E1 
NTU for repair or for verification of shipping damage.

Figure 2.  Typical System Application

Table 1.  Compliance Codes

Code

Input

Output

Power Code (PC)

F

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Network

Management

System

VT100

VT100

Total Access 3000

SHDSL

T1/E1

LTU

SHDSL

T1/E1

NTU

1

B

A

SCU

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

SCU

FSE

MODE

ALM

HST

ACO

C

R

A

F

T

ACO

SELECT

1181018L1

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

2

1

P

O

R

T

PWR

3

4

LTU

1181308L1

OPT

Customer T1 or E1

Equipment

(e.g., PABX)

1225236L1

T1/E1

SHDSL

PWR

TEST

ALM

SHDSL

NTU

2-Wire Twisted Pair

Содержание 1225236L1

Страница 1: ...1 NTU is a network terminating module using Single Pair High Speed Digital Subscriber Line SHDSL technology to transport data over a single copper loop Revision History This is the initial issue of th...

Страница 2: ...ssible keep the original shipping container for returning the SHDSL T1 E1 NTU for repair or for verification of shipping damage Figure 2 Typical System Application Table 1 Compliance Codes Code Input...

Страница 3: ...ons The SHDSL T1 E1 NTU is designed for a T200 or T400 type form factor housing and inserts into the customer T1 or E1 T200 type equipment Follow local practice for installation of the SHDSL T1 E1 NTU...

Страница 4: ...The menu tree in Figure 3 illustrates the path to every provisioning performance and test access point in the SHDSL T1 E1 menu system Table 4 lists the complete set of configurable options with setti...

Страница 5: ...payload i e G 703 or entire SHDSL payload The PRBS used in the SHDSL T1 E1 NTU is PRS15 as defined in ITU T 0 150 and 0 151 It is also known as 2e15 1 pattern Customer Port The SHDSL T1 E1 NTU operat...

Страница 6: ...iolations Count CVC LOSW Seconds LOSWS Loopback Status BERT Status General Status Data Rate Framing Mode Errored Seconds ES Severely Errored Seconds SES Unavailable Seconds UAS Code Violations Count C...

Страница 7: ...1 to 15db Alarm Threshold Disabled Loop Attenuation Alarm Threshold 0 Disabled 1 to 127db Alarm Threshold Disabled ES 15 Minute Alarm Threshold 0 Disabled 1 to 900 Seconds Alarm Threshold Disabled SE...

Страница 8: ...led Table 4 Configuration Options List Continued Category Option Setting Default Table 5 E1 Port Statistics Definitions Statistic Framing Mode Definition Errored Seconds ES Unframed LOS condition or B...

Страница 9: ...Mode Definition Errored Seconds ES Unframed LOS condition or BPV s 0 SF LOS or LOF condition or if BPV s 0 or FE s 0 ESF LOS or LOF condition or if BPV s 0 or FE s 0 Severely Errored Seconds SES Unfr...

Страница 10: ...10 Issue 1 August 2003 61225236L1 5A...

Отзывы: