background image

Section 61225236L1-5A

Issue 1, August 2003

61225236L1-5A

    1

Trademarks: Any brand names and product names included in this document are 

trademarks, registered trademarks, or trade names of their respective holders.

CONTENTS

1. General ................................................................... 1
2. Description ............................................................. 1
3. Installation.............................................................. 2
4. Provisioning ........................................................... 4
5. Operation................................................................ 5
6. Maintenance ........................................................... 9
7. Specifications ......................................................... 9
8. Warranty and Customer Service ............................ 9

FIGURES

Figure 1. SHDSL T1/E1 NTU Front Panel................ 1
Figure 2. Typical System Application ....................... 2
Figure 3. SHDSL T1/E1 NTU Menu Tree................. 6

TABLES

Table 1. Compliance Codes ...................................... 2
Table 2. DB-9 Connector Pin Descriptions .............. 3
Table 3. Front Panel LEDs ....................................... 4
Table 4. Configuration Options List ......................... 7
Table 5. E1 Port Statistics Definitions...................... 8
Table 6. T1 Port Statistics Definitions...................... 9
Table 7. SHDSL T1/E1 NTU Specifications............ 9

1. GENERAL

This document is an installation and maintenance 
practice for the ADTRAN Total Access® SHDSL T1/
E1 Network Terminating Unit (NTU). 

Figure 1

 illus-

trates the SHDSL T1/E1 NTU front panel, P/N 
1225236L1.The SHDSL T1/E1 NTU is a network 
terminating module using Single-Pair High Speed 
Digital Subscriber Line (SHDSL) technology to 
transport data over a single copper loop.

Revision History

This is the initial issue of this practice. Future changes 
to this documentation will be explained in this 
subsection.

2. DESCRIPTION

The SHDSL T1/E1 NTU was designed for use as a 
remote unit to the Total Access 3000. The Total Access 
SHDSL T1/E1 NTU provides an interface between the 
SHDSL network and the customer’s Data Terminal 
Equipment (DTE) for applications such as LAN to LAN 
bridging, Frame Relay circuit, and PABX termination.

Figure 1.  SHDSL T1/E1 NTU Front Panel

The SHDSL T1/E1 NTU is span powered with local DC 
power auto-switchover. No adjustments, strapping, or 
configuration changes are necessary to power the 
module. The SHDSL T1/E1 NTU configuration, 
testing, and performance monitoring is managed by the 
VT100 local management screen menus, remotely by an 
EOC terminal session, or also remotely by EOC 
message protocol initiated by the Total Access SHDSL 
T1/E1 LTU. 

1225236L1

T1/E1

SHDSL

PWR

TEST

ALM

SHDSL

NTU

V.

2

4

T200 SHDSL T1/E1 Network Terminating Unit

Installation and Maintenance Practice

Содержание 1225236L1

Страница 1: ...1 NTU is a network terminating module using Single Pair High Speed Digital Subscriber Line SHDSL technology to transport data over a single copper loop Revision History This is the initial issue of th...

Страница 2: ...ssible keep the original shipping container for returning the SHDSL T1 E1 NTU for repair or for verification of shipping damage Figure 2 Typical System Application Table 1 Compliance Codes Code Input...

Страница 3: ...ons The SHDSL T1 E1 NTU is designed for a T200 or T400 type form factor housing and inserts into the customer T1 or E1 T200 type equipment Follow local practice for installation of the SHDSL T1 E1 NTU...

Страница 4: ...The menu tree in Figure 3 illustrates the path to every provisioning performance and test access point in the SHDSL T1 E1 menu system Table 4 lists the complete set of configurable options with setti...

Страница 5: ...payload i e G 703 or entire SHDSL payload The PRBS used in the SHDSL T1 E1 NTU is PRS15 as defined in ITU T 0 150 and 0 151 It is also known as 2e15 1 pattern Customer Port The SHDSL T1 E1 NTU operat...

Страница 6: ...iolations Count CVC LOSW Seconds LOSWS Loopback Status BERT Status General Status Data Rate Framing Mode Errored Seconds ES Severely Errored Seconds SES Unavailable Seconds UAS Code Violations Count C...

Страница 7: ...1 to 15db Alarm Threshold Disabled Loop Attenuation Alarm Threshold 0 Disabled 1 to 127db Alarm Threshold Disabled ES 15 Minute Alarm Threshold 0 Disabled 1 to 900 Seconds Alarm Threshold Disabled SE...

Страница 8: ...led Table 4 Configuration Options List Continued Category Option Setting Default Table 5 E1 Port Statistics Definitions Statistic Framing Mode Definition Errored Seconds ES Unframed LOS condition or B...

Страница 9: ...Mode Definition Errored Seconds ES Unframed LOS condition or BPV s 0 SF LOS or LOF condition or if BPV s 0 or FE s 0 ESF LOS or LOF condition or if BPV s 0 or FE s 0 Severely Errored Seconds SES Unfr...