NCT-04/03/02 Punch CNC System (Commissioning Manual)
1
Preparation
1.1
Power Requirements
Output voltage: DC24V/6A, precision error ±10%;
Power lines should be placed separately, and away from the welding machine, and other equipment that has
larger impact on current fluctuations; add filter if necessary;
For specific anti-jamming measures, refer to "Maintenance Manual" 11.1.3 Installation Considerations;
1.2
Relationship between Self-diagnosis and Voltage Level
1.3
Parameter Description
P1 - P5 indicate comprehensive, axis configuration, management, mold, and port respectively;
#
Example
P5.061 indicates No. 061 "port" parameter, external start 2 detection port number;
#
Port settings are invalid
Input "8888" in the "Input" mode;