![Adtech NCT-02 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/adtech/nct-02/nct-02_user-manual_2854144007.webp)
NCT-04/03/02 Punch CNC System (Commissioning Manual)
2
Commissioning
2.1
Preparation before Commissioning
Before commissioning motion axes, adjust the emergency stop signal, hard limit and soft limit function to
prevent machine tool crash due to misuse in the commissioning process of other features; for details, please
refer to "NCT-XX Maintenance Manual": 8 Safe Operation;
2.1.1
Emergency Stop
Emergency stop button: Control Panel
Reset; additional panel:
STOP
External emergency stop port configuration: P5.058;
External emergency stop port effective level: P1.056;
2.1.2
Hard Limit
Hard limit port number: X-: 17, X +: 18, Y-: 19, Y-: 20
X hard limit effective level: P2.019;
Y hard limit effective level: P2.022;
2.1.3
Soft Limit
If the hard limit isn’t installed, soft limit must be set to protect the machine;
Related parameters: P1.021 - P1.024
0
Note
Soft limit coordinates are based on mechanical coordinates;
2.2
Debugging Motion Axes (X/Y)
Basic functions commissioning of X, Y-axis and the drive;
X axis for example;
Given: the minimum resolution of the controller is 0.01mm; requires servo alarm function and alarm clear
function; please set the relevant parameters;
2.2.1
Drive Connections
Controller X-axis output port: XS1; for port definition, see "NCT-XX Maintenance Manual" 11.2.1 Control
Interface of Motor Drive;
11.3.3 Servo drive connection diagram;
0
Note
Connect the cable of XS1; it is prohibited to short unused lines!
2.2.2
System Gear Ratio Setting
For the setting of system gear ratio, refer to "NCT-XX Maintenance Manual" 10.2 Comprehensive
Parameters (P1.) 001 ~ 008;