ADTECH9 Series CNC Maintenance Manual
- 150 -
A Ext Home Enable
B Ext Home Enable
C Ext Home Enable
Range :
0~1
Unit
:
None
Authority
:
Super
Admin
Default :
1
Effective
time
:
Instant
Note
:
When mechanical home mode is selected, this parameter determines
whether external deceleration switch should be searched. If this parameter
is set to 0, and P2.015 (servo Z phase enable) is also set to 0, the home
mode sets current point as the home directly in mechanical mode.
0: No
1: Yes
038
X Encoder Logic Dir
Y Encoder Logic Dir
Z Encoder Logic Dir
A Encoder Logic Dir
B Encoder Logic Dir
C Encoder Logic Dir
Range :
0~1
Unit
:
None
Authority
:
Super
Admin
Default :
0
Effective
time
:
Instant
Note
:
When the logic direction obtained by handheld box encoder is reverse to
the actual motion direction of the axis, set this parameter to perform
in-phase setting.
0: positive direction
1: negative direction
039
X-axis return-to-zero 2
nd
segment leave speed
Содержание CNC9 Series
Страница 1: ...ADTECH 9 Series CNC Maintenance Manual ...
Страница 18: ...ADTECH9 Series CNC Maintenance Manual 13 2 2ADTCNC99 and 98 series system LCD keypad ...
Страница 19: ...ADTECH9 Series CNC Maintenance Manual 14 ...
Страница 45: ...ADTECH9 Series CNC Maintenance Manual 40 ...
Страница 216: ...ADTECH9 Series CNC Maintenance Manual 211 11 3 2 Power connection diagram ...
Страница 217: ...ADTECH9 Series CNC Maintenance Manual 212 11 3 3 Servo driver connection diagram ...
Страница 218: ...ADTECH9 Series CNC Maintenance Manual 213 11 3 4 Step connection diagram ...
Страница 219: ...ADTECH9 Series CNC Maintenance Manual 214 11 3 5 IO electrical connection diagram ...
Страница 220: ...ADTECH9 Series CNC Maintenance Manual 215 ...
Страница 221: ...ADTECH9 Series CNC Maintenance Manual 216 ...
Страница 247: ...ADTECH9 Series CNC Maintenance Manual 242 Select to upload and download files in the file management bar ...
Страница 249: ...ADTECH9 Series CNC Maintenance Manual 244 ...