8.1.2
Relative Position
In manual mode, reset current coordinates to check the relative motion distance of any displacement, and thus it
is called as relative position.
This interface is usually used for early tool setting. Considering that some operators have been used to manual
calculation, this function is preserved. With more and more powerful automatic centered function, it is less used.
The operation is as follows:
Enter [Position] interface;
Switch to [Relative] interface;
Then, enter manual mode;
Press a coordinate axis No., e.g., ‘X’, and the X coordinate flashes;
Press “Cancel” to reset X coordinate to 0;
The relative position interface is as follows:
Relative Position Interface
Содержание CNC9 Series
Страница 1: ...ADTECH 9 Series CNC Maintenance Manual ...
Страница 18: ...ADTECH9 Series CNC Maintenance Manual 13 2 2ADTCNC99 and 98 series system LCD keypad ...
Страница 19: ...ADTECH9 Series CNC Maintenance Manual 14 ...
Страница 45: ...ADTECH9 Series CNC Maintenance Manual 40 ...
Страница 216: ...ADTECH9 Series CNC Maintenance Manual 211 11 3 2 Power connection diagram ...
Страница 217: ...ADTECH9 Series CNC Maintenance Manual 212 11 3 3 Servo driver connection diagram ...
Страница 218: ...ADTECH9 Series CNC Maintenance Manual 213 11 3 4 Step connection diagram ...
Страница 219: ...ADTECH9 Series CNC Maintenance Manual 214 11 3 5 IO electrical connection diagram ...
Страница 220: ...ADTECH9 Series CNC Maintenance Manual 215 ...
Страница 221: ...ADTECH9 Series CNC Maintenance Manual 216 ...
Страница 247: ...ADTECH9 Series CNC Maintenance Manual 242 Select to upload and download files in the file management bar ...
Страница 249: ...ADTECH9 Series CNC Maintenance Manual 244 ...