background image

–  16  – 

 

Force Upload of Configuration File to Server 

Pressing [Y] will force the device to upload its entire 
configuration file to the server. 
Pressing [N] cancels the operation.  

NOTE:

   If the GSMVLP-ADT module is not initialized when you enter this 

command, the following screen will be displayed: 

Cannot Upload 
Try Later! _

 

 

[0] 

 

 

Force Server 
Update? 

Y/N 

 

Wait for the RSSI LEDs to light, indicating the GSMVLP-ADT 
module has completed its initialization, and try again.

 

[ENTER] 

 

Strt Prog Mode? 

 

Y/N_ 

 

Enter Program Mode 

Press [Y] to enter program mode; otherwise, press [N].

 

 

 
 

Содержание GSMVLP-ADT

Страница 1: ...GSMVLP ADT GSM Module with 2 Way Voice Installation and Programming Guide 800 04954 1 11 09 Rev A...

Страница 2: ...P Mode Programming 7 Setting up the Multi Mode Feature 9 Configuring Multi Mode 9 Setting up the Remote Access Feature 10 Enabling Remote Access 10 Selecting the User Interface 11 ECP Status Codes 12...

Страница 3: ...and central station via GSM Sends reports in Contact ID format Supports remote control of alarm system via Remote Services Feature Fully powered primary and backup battery from the control The GSMVLP...

Страница 4: ...d floor Opening the ADT QuickConnect 3000 Control and Installing GSMVLP ADT 1 Install the provided IC label P N 800 05101 on the control s back case as shown on Figure 2 GSMVLP 005 V0 CONTAINS TRANSMI...

Страница 5: ...cable provides DC power and ground for the module and ECP connections 6 Make the wiring connections and install the control in accordance with the ADT QuickConnect 3000 Installation Instructions 7 Re...

Страница 6: ...you are already signed up for this service go to https services alarmnet com AlarmNetDirect userlogin aspx If you are not signed up for this service click on Dealer Sign Up Log in and follow the on sc...

Страница 7: ...FT KEY FUNCTION BS ESC BS Press to delete entry ESC Press to quit program mode also can reset programming defaults Scroll down programming Scroll up programming N Y N Press for NO answer Y Press SHIFT...

Страница 8: ...ring center can remotely block access to local device programming If this has been done the following prompt appears Access to Prog Mode Denied Table 2 Programming the GSMVLP ADT Module NOTE The defau...

Страница 9: ...therwise the Exit Prog Mode prompt is displayed directly 8 Exit Prog Mode Y N _ Y N ESC Exits program mode Press N to go back to Prompt 3 Press ESC to load factory defaults Refer to the Exiting Progra...

Страница 10: ...5 It MUST be programmed with a valid IP address 17 CS1 Port 443 _ 0 65535 Enter the internet port of the first CS receiver that the device will report to 18 CS2 IP 255 255 255 255_ 12 digit IP Address...

Страница 11: ...ed if using Remote Access For the Lynx Plus and ADT Safewatch QuickConnect 3000 panel the address must be 01 28 Supervision 24 Hours _ 30 Day 24 Hour None The GSMVLP ADT will send one status message i...

Страница 12: ...graph at the end of this section ECP Status Codes The GSMVLP ADT sends status messages to the control panel to indicate general failures The control will display FAULT 103 if any of the events listed...

Страница 13: ...key refer to the Programmer Keyboard Commands section Setting Factory Defaults To reset the programming options to factory default values press ESC at the Exit Prog Mode prompt Set Default Y N_ Press...

Страница 14: ...pace key to go to the next field Press the backspace key to go to the previous field SCID xxxxx xxxxx xxxxx xxxxx SCID Display Displays the identification number assigned to the SIM card SCID in this...

Страница 15: ...ce key to go to the previous field Cell BaseSt Chan xxxxx x xxx GSMVLP ADT Status Display Screen 3 Cell Base Station ID BaseSt Base Station Antenna Sector Chan Control Channel in use Press the space k...

Страница 16: ...TE If the GSMVLP ADT module is not initialized when you enter this command the following screen will be displayed Cannot Upload Try Later _ 0 Force Server Update Y N Wait for the RSSI LEDs to light in...

Страница 17: ...t the minimum required signal strength for installation exists between the module and the receiving tower Refer to Figure 8 Table 3 Status and Signal Strength LED Operation LED COLOR LED DESCRIPTION G...

Страница 18: ...onditions listed below Table 4 GSMVLP ADT Central Station Messages Alarm Condition ECP Mode Alarm Code ECP Mode Restore Code Power On Reset E339 C0803 ECP Supervision E355 C0000 R355 C0000 Communicati...

Страница 19: ...ripheral devices consists of a four wire data bus power data in out GPRS General Packet Radio Service GSM Global System for Mobile communications which is an international standard for digital mobile...

Страница 20: ...0 SPECIFICATIONS 1 Physical Dimensions 5 625 x 2 25 2 Electrical Input Voltage 12VDC nominal powered by the ADT QuickConnect 3000 Control Panel Quiescent Current 40mA Peak Current During Transmit 650m...

Страница 21: ...21 NOTES...

Страница 22: ...22 NOTES...

Страница 23: ...23 NOTES...

Страница 24: ...ADT Security Services Inc One Town Center Road Boca Raton FL 33486 Copyright 2009 800 04954 1 800 04954 1 11 09 Rev A...

Отзывы: