– 21 –
5800 Series Transmitter Input Loop Identification
• All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes.
Each of the
inputs requires its own programming zone
(e.g., a 5804's four inputs require four programming zones).
All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the input
loops requires its own programming zone
(e.g., a 5804's four inputs require four programming zones).
LOOP 1
5806/5806W3
5808/5808LST/5808W3
ENROLL AS "RF"
LOOP 1
5809
ENROLL AS "RF"
5 8 1 8 M N L
ENROLL AS "RF"
LOOP 1
LOOP 1
5814
ENROLL AS "RF"
5800-003-V0
LOOP 1
(MOTION)
5897-35
ENROLL AS "RF"
5 8 9 0 / 5 8 9 0 P I
ENROLL AS "RF"
LOOP 1
5 8 0 2 M N
ENROLL AS
"UR" OR "RF"
5 8 0 5 - 6
ENROLL AS "BR"
5 8 0 4 B D / 5 8 0 4 B DV
ENROLL AS "BR"
SET HOUSE ID
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP
3
LOOP 1
LOOP 2
•
•
••
•
•
••
•
•
•
• •
• •
•
•••
5804/5804E
ENROLL AS "BR"
5 8 1 7
ENROLL AS "RF"
LOOP 2
(AUX.
CENTER)
LOOP 1
(PRIMARY)
LOOP 3
(AUX.
RIGHT)
5 8 1 6
ENROLL AS "RF"
LOOP 1
(TERMINALS)
LOOP 1
(TERMINALS)
LOOP 2
(REED)
5 8 1 6 M N
ENROLL AS "RF"
LOOP 1
(TERMINALS)
ALTERNATE
POSITION FOR
LOOP 2
LOOP 2
(REED)
LOOP 3
(TERMINALS)
5 8 2 8 / 5 8 2 8 V
SET HOUSE ID
5 8 1 5
ENROLL AS "RF"
5 8 2 0 / 5 8 2 0 L
ENROLL AS "RF"
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
5 8 1 9
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
5 8 0 0 WAV E
S E T H O U S E I D
E N RO L L A S " R F "
5 8 0 0 M i c r a
E N R O L L A S " R F "
5 8 0 0 C O
E N R O L L A S " R F "
5 8 0 1
E N RO L L A S
" U R O R " R F "
5 8 0 0 S S 1
E N RO L L A S " R F "
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
5 8 9 4 P I
ENROLL AS "RF"
5 8 0 2 M N 2
ENROLL AS
"UR" OR "RF"
LOOP 1
LOOP 1
LOOPS
1 - 3
LOOP 1
LOOP 1
LOOP 1
LOOP
1
LOOP 1
LOOP
1
LOOP
1
5 8 7 8
ENROLL AS "BR"
5 8 5 3
ENROLL AS "RF"
ARMED
READY
MESSAG
E
MIC
4
3
2
1
OFF
ON
5 8 2 1
ENROLL AS "RF"
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 1
LOOP 2
LOOP 3
SERIAL #1
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 3
SERIAL #1
LOOP 2
SERIAL #1
LOOP 1
SERIAL #2
LOOP 2
SERIAL #1
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 3
SERIAL #1
LOOP 2
SERIAL #1
LOOP 1
SERIAL #2
LOOP 2
3
AW
AY
STA
Y
1
2
4
OFF
ON
LOOP 2
(REED)
LOOP 2
(REED)
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS
LOOP 4 = 3 + 4 BUTTONS
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS
LOOP 4 = 3 + 4 BUTTONS
NOTE
: For information on any transmitter not shown, refer to the instructions accompanying that transmitter for details
regarding loop numbers, etc.
UL NOTE:
The following transmitters are not intended for use in UL installations:
5802, 5802MN, 5802MN2, 5804E, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, and 5850.
Wireless Key Predefined Default Templates
For 5804
Loop
Function
Zone Type
For 5804BD
Loop
Function
Zone Type
TEMPLATE 1
1
No Response
23
TEMPLATE 4
1
No Response
23
2
Disarm
22
2
No Response
23
3
Arm Away
21
3
Arm Away
21
4
No Response
23
4
Disarm
22
TEMPLATE 2
1
No Response
23
TEMPLATE 5
1
No Response
23
2
Disarm
22
2
Arm Stay
20
3
Arm Away
21
3
Arm Away
21
4
Arm Stay
20
4
Disarm
22
TEMPLATE 3
1
No Response
23
TEMPLATE 6
1
No Response
23
2
Disarm
22
2
Arm Stay
20
3
Arm Away
21
3
Arm Away
21
4
Arm Stay
20
4
Disarm
22