background image

4

Chapter 1 Introduction

Features

This section provides an overview of the features. For more detailed  information, please refer 

to the technical specifi cations appendix at the end of this manual .Your Disk Array includes the 

following features : 

Easy Operation

As everyone knows, conventional Disk Arrays are designed for experienced computer specialists. 

To solve complicated and time consuming operating procedures, we came up with a revolutionary 

idea: 

--  Innovative Plug And Play RAID --

As compared to a conventional Disk Array’s long-winded setup    procedures, your Disk Array can 

be ready to go after using the simple step by step built-in setup program.

Ultra High Performance

Your Disk Array combines an extremely high speed microprocessor with the latest chip 

set, IDE hardware technology, perfect fi rmware and an artistic design. The result is one of 

the fastest, most reliable Disk Array systems on the market.

IEEE1394 interface to your Host computer, up to 400Mbits data transfer rate provides the 

processing and access power for you to handle complex and large fi les.

Selective RAID levels 0, 1, 0+1, 3 or 5.

Built-in 64MB cache memory, expandable up to 512MB.

Serial communication port (Terminal Port ) permits array controller   operation through a 

standard VT100 terminal (or equivalent).

Solid reliability

Automatic failed disk drive detection.

Auto rebuild : when a replacement disk installed (or by using hot  spare disk ),

The system provides automatic data rebuild without any commands or functions keyed in. 

( Transparent to Host )

Effi cient maintenance

An LCD status panel displays a comprehensive readout of the  operating status, and the 

HDD LED indicators on each HDD tray  display the individual HDD status. 

When disk failure occurs on a member disk of the disk array, the  built-in buzzer sounds  

simultaneously and LCD status panel  also points out the location of the failed hard disk 

drive. The LED HDD status indicator will light up “ Red “on the failed HDD tray. You  can 

perform quick, effi cient and correct maintenance. 

Hot Swap : you can remove, install, then “ Hot Swap “ parts without interrupting data 

access while the system is on.

The “ Hot Swap “ parts include the Hard Disk Drive and Cooling Fan.                                              

          

Содержание API-960

Страница 1: ...com Technical Support 562 926 4338 Technical Support Hours Technical Support Technical Support Hours Technical Support 8am 5pm M F PST Technical Support 8am 5pm M F PST Technical Support PYRO DV RaidR...

Страница 2: ...0 6 RAID Level 1 7 RAID Level 3 8 RAID Level 5 9 Summary Comparison of RAID Levels 10 Supported RAID Levels 11 Chapter 2 Getting Started General Overview 12 Unpacking Checklist 12 Choosing a place fo...

Страница 3: ...the supply voltage 9 The appliance must be grounded This product is equipped with a 3 wire grounding type power cord this power cord will only fit into a grounding type power outlet 10 If an extension...

Страница 4: ...xtreme heat or cold Warning The Disk Array s LCD Panel may be damaged by exposure to intense sunlight Limit exposure to indirect or subdued sunlight only Your Disk Array should be used in a clean envi...

Страница 5: ...des the processing and access power for you to handle complex and large files Selective RAID levels 0 1 0 1 3 or 5 Built in 64MB cache memory expandable up to 512MB Serial communication port Terminal...

Страница 6: ...drives typically two to six which appear to the user to be equivalent to a single large capacity disk drive The remarkable benefit of disk array is that if any single disk in the RAID fails the syste...

Страница 7: ...libraries for rapid loading these libraries are normally read only Storing large tables or other structures of read only data for rapid application access Like program images the data should be backed...

Страница 8: ...nagement software simply directs all application requests to the surviving member RAID level 1 is suitable for data for which reliability requirements are extremely high or for data to which high perf...

Страница 9: ...e of these types They operate on large data objects such as graphical image processing CAD CAM files and others They are non interactive applications that process large data sequentially They usually...

Страница 10: ...hanced availability is worth protecting but for which the value of full disk mirroring is questionable High read request rates Small percentage of writes in I O load RAID level 5 arrays have unique pe...

Страница 11: ...h provided 1 Mirroring All data Duplicated 1 disk Very High High 3 Parallel Data sector is subdivided N 1 Very Highest Transfer and distributed across all disks High of all Disks with data disk Redund...

Страница 12: ...ction Disk Mirroring Disk drives are mirrored 1 All data is 100 duplicated on each 2 4 equivalent disk drives High Data Reliability Parallel Transfer Disks with Parity 3 Data is striped across physica...

Страница 13: ...for doing regular backup It s highly recommended to conduct a backup strategy for critical data Unpacking Checklist Before unpacking your Disk Array prepare a clean and stable place to put the content...

Страница 14: ...trolled by wall switches or automatic timers Accidental disruption of the power source may wipe out data in the memory of your computer or Disk Array Keep the entire system away from potential sources...

Страница 15: ...n either on AC 115V 10 or AC 230V 10 Slide the AC voltage select switch on the power supply to the correct position which corresponds with the wall outlet supply voltage Warning Wrong AC Voltage input...

Страница 16: ...2 Gently Pull out the HDD tray SCREWS SCREWS Cabling Step 3 Insert HDD into the tray Step 4 Screw in the hard drive Use the correct size type and thread Step 5 Cabling Connect the Data cable and Powe...

Страница 17: ...ot installed or error 4 HDD Access Indicator light up Yellow when HDD is access 1 2 3 4 ESC Enter Chapter 2 Getting Started POWER ON AND SELF TEST When you connect the Disk Array to the Host computer...

Страница 18: ...ol or icon corresponding to that function will appear in the display window The symbol will remain in the display window indicating the status of the Disk Array Identifying the status on the LCD The f...

Страница 19: ...e to connect your Host computer to the Disk Array s built in IEEE 1394 adapter port Connect the Host computer as shown below Figure Host Linkage Chapter 2 Getting Started Caution For safety reasons ma...

Страница 20: ...changes to the configuration and tailor your Disk Array to your individual needs The setup program is a ROM based configuration utility which displays the Disk Array s Status and allows you to set up...

Страница 21: ...rformed through this interface Function Key Definitions The four function keys at the top of the front panel perform the following functions Up Arrow Right Arrow Use the scroll the cursor Upward Right...

Страница 22: ...on 6 Set Hot Spare Disk Select Yes to set one Disk Drive as a Hot spare Disk Valid for RAID Level 5 and 3 the total number of Disk Drives installed must be more than 3 Disk Drives 7 Set Password Press...

Страница 23: ...configure the VT100 terminal settings to the values shown below VT100 Termnal or compatible Set up Connection Serial Port COM1 or COM2 Protocol RS232 Asynchronous Cabling Null Modem cable Baud Rate 11...

Страница 24: ...23 CONFIGURATION PROCEDURES VT100 Terminal CONFIGURATION PROCEDURES VT100 Terminal Chapter 3 CONFIGURATION MAIN SCREEN...

Страница 25: ...D Select No for setting Password Select Yes for setting all the configurations SET RAID LEVEL Move the cursor to the desired RAID Level 0 1 3 5 0 1 None and Press Enter to confirm it Warning All Data...

Страница 26: ...id in RAID level 5 and RAID level 3 the total Disk Drives installed must be more than 3 Disk Drives Disk Drives number 3 Chapter 3 CONFIGURATION SET PASSWORD Press Enter to activate the password setti...

Страница 27: ...be lost if you change the RAID level Warning Saving configuration changes causes the disk array controller s working parameters to change This can produce unpredictable results if it occurs during Hos...

Страница 28: ...Disk Array comes with 64MB of memory that is expandable to a maximum of 512MB These expansion memory module can be purchased from your dealer Memory Type 3 3V PC100 133 SDRAM 144pin DIMM Memory Size...

Страница 29: ...Install the memory a The DIMM memory modules will only fit in one orientation b Press the memory module firmly into socket from a 45 degree angle make sure that all the contacts are aligned with the...

Страница 30: ...NCED INFORMATION Host channel NVRAM LCD Terminal Port PCI BUS i960RM Local BUS PCI Bridge Main memory i960RM RISC Micro processor Flash EPROM Dual Channel IDE Controller Disk 1 Disk 2 Dual Channel IDE...

Страница 31: ...2 Step 3 Enter a name for your Terminal Please configure the VT100 terminal setting to the values shown below VT100 terminal or compatible set up Connection Serial Port COM1 or COM2 Protocol RS232 As...

Страница 32: ...31 Chapter 4 ADVANCED INFORMATION UPDATING FIRMWARE CONT D UPDATING FIRMWARE CONT D Step 4 Select a connecting port in your Terminal Step 5 Port parameter settings Step 6...

Страница 33: ...Step 7 Select emulate VT100 model After you have finished the VT100 Terminal setup you may restart your Disk Array and press Ctrl D keys in your Terminal to linkthe Disk Array and Terminal together P...

Страница 34: ...ess Y to download the new firmware and press Y again to confirm the Update WARNING Unpredictable results will occur if firmware update is attempted during Host computer and Disk Array activity All act...

Страница 35: ...PC Step 5 Press Go to confirm to download the new firmware Step 6 Type Go to reconfirm and the firmware will begin to be reprogrammed Step 7 After verifying please restart the Disk Array to activate t...

Страница 36: ...e the disk array is on The Hot Swap parts include Hard Disk Drives Cooling Fans Follow the steps below and refer to the diagrams to remove and install the Hot Swap parts REMOVING INSTALLING HARD DISK...

Страница 37: ...isk Array s built in buzzer will sound and the intelligent Auto Rebuild function will not be started For best performance we recommend you swap with an identical Hard Disk Drive Step 5 Gently Slide in...

Страница 38: ...e Step 2 Unplug the Fan connector Step 3 Unscrew the faulty cooling fan and replace with a good one Important The cooling fan s air flow must point to the fan door please refer to the label on the coo...

Страница 39: ...EEPROM 256K x 8 Hardware XOR Accelerate Build In IEEE 1394 I O Processor TI TSB43AB22 Serial Port 1x RS232 Asynchronous Port Ba ud Rate 115 200 Bits Per Second Da ta Bits 8 Sto p Bit 1 Pari ty None R...

Страница 40: ...Fans Power Supply Capacity 200W AC Input Voltage 115 230V 10 60 50 Hz Environmental Relative Humidity 10 to 85 Non condensing Temperature Operating 5 J 40 J Storage 25 J 60 J Safety testing Under appl...

Страница 41: ...pped products 4 Replacement product cannot be shipped to you until the defective product has been received by ADS 5 Once the product is received at the factory it will be tested and then repaired or r...

Страница 42: ...erican Office 12627 Hidden Creek Way Cerritos CA 90703 Phone 562 926 1928 Technical Support 562 926 4338 Technical Support Hours M F 8am 5pm PST Fax 562 926 0518 European Office Shannon Industrial Est...