76
Operation Theory
4.6
The Comparators
There are 5 counter comparators of each axis. Each comparator
has dedicated functions. They are:
1. Positive soft end-limit comparator to command counter
2. Negative soft end-limit comparator to command counter
3. Command and feedback error counter comparator
4. General comparator for all counters
5. Trigger comparator for all command and feedback
counters
4.6.1
Soft end-limit comparators
There are two comparators for end-limit function of each axis. We
call them for the soft end-limit comparators. One is for plus or pos-
itive end-limit and the other is for minus or negative end-limit. The
end-limit is to prevent machine crash when over traveling. We can
use the soft limit instead of a real end-limit switch. Notice that
these two comparators only compare the command position
counter. Once the command position is over the limited set inside
the positive or negative comparators, it will stop moving as it
touches the end-limit switch.
4.6.2
Command and feedback error counter comparators
This comparator is only for command and feedback counter error.
Users can use this comparator to check if the error is too big. It
can be set a action when this condition is met. The actions include
generating interrupt, immediately stop, and deceleration to stop.
4.6.3
General comparator
The general comparator let users to choose the source to com-
pare. It could be chosen from command, feedback position
counter, error counter or general counter. The compare methods
could be chosen by equal, greater than or less than with direc-
tional or direction-less. Also the action when condition is met can
be chosen from generating interrupt, stop motion or others.
Содержание PCI-8174
Страница 4: ......
Страница 13: ...Introduction 3 Figure 1 2 Flow chart for building an application ...
Страница 94: ...84 Operation Theory ...
Страница 98: ...88 MotionCreatorPro 5 3 2 Select Menu The select menu appears after running MotionCreatorPro It is used to ...
Страница 99: ...MotionCreatorPro 89 5 3 3 Card Information Menu In this menu it shows some Information about this card ...
Страница 100: ...90 MotionCreatorPro 5 3 4 Configuration Menu In this menu users can configure ALM INP ERC EL ORG and EZ ...
Страница 102: ...92 MotionCreatorPro In this menu users can configure LTC SD PCS and Select_Input ...
Страница 104: ...94 MotionCreatorPro In this menu users can configure pulse input output and move ratio and INT factor ...
Страница 166: ...156 Function Library ...
Страница 168: ...158 Connection Example ...