68
Operation Theory
4.3.3
In position signal
The in-position signal is an output signal from motor driver. It tells
motion controllers a motor has been reached a position within a
predefined error. The predefined error value is in-position value.
Most motor drivers call it as INP value. After motion controller
issues a positioning command, the motion busy status will keep
true until the INP signal is ON. Users can disable INP check for
motion busy flag. If it is disabled, the motion busy will be FALSE
when the pulses command is all sent.
4.3.4
Servo alarm signal
The alarm signal is an output signal from motor driver. It tells
motion controller that there has something error inside servo
motor or driver. Once the motion controller receives this signal, the
pulses command will stop sending and the status of ALM signal
will be ON. The reasons of alarm could be servo motor’s over
speed, over current, over loaded and so on. Please check motor
driver’s manual about the details.
The logic of alarm signal must be set correctly. If the alarm logic’s
setting is not the same as motor driver’s setting, the ALM status
will be always ON and the pulse command can never be output-
ted.
Содержание PCI-8174
Страница 4: ......
Страница 13: ...Introduction 3 Figure 1 2 Flow chart for building an application ...
Страница 94: ...84 Operation Theory ...
Страница 98: ...88 MotionCreatorPro 5 3 2 Select Menu The select menu appears after running MotionCreatorPro It is used to ...
Страница 99: ...MotionCreatorPro 89 5 3 3 Card Information Menu In this menu it shows some Information about this card ...
Страница 100: ...90 MotionCreatorPro 5 3 4 Configuration Menu In this menu users can configure ALM INP ERC EL ORG and EZ ...
Страница 102: ...92 MotionCreatorPro In this menu users can configure LTC SD PCS and Select_Input ...
Страница 104: ...94 MotionCreatorPro In this menu users can configure pulse input output and move ratio and INT factor ...
Страница 166: ...156 Function Library ...
Страница 168: ...158 Connection Example ...