70
•
Function Library
♦
Home Return Mode:
Press “Home Move” button will enable Home Return motion. The home
returning velocity is specified by settings in Motion Parameters Control.
The arriving condition for Home Return Mode is specified in Axis
Configuration Window. Press
→
to begin returning home function. Press
“STOP” to stop moving.
♦
Manual Pulser Mode:
Press “Manual Pulser Move” button will enable motion controlled by hand
wheel pulser. Using this function, user can manually operate the axis thus
verify operation. The maximum moving velocity is limited as specified by
“Maximum Velocity”. Press “STOP” to end this mode.
Do remember to press “STOP” to end operation under this mode.
Otherwise, operations under other modes will be inhibited.
5.3.6 Motion Parameters Control
Use the Motion Parameters with the Operation Mode Control to command
motion.
Ÿ
Starting Velocity: Specify the starting moving speed in pulses per
second.
Ÿ
Maximum Velocity: Specify the maximum moving speed in pulses
per second.
Ÿ
Acceleration: Specify the acceleration in pulses per second
square.
Ÿ
Move delay: Specify time in mini seconds between movement.
Ÿ
S curve Acc/dec Time: Specify time in mini second for S_curve
Movement.
5.3.7 Play Key Control
Use buttons in Play Key Control to begin or end operation.
: click button under this symbol to begin moving to Positions 2 in Absolute
Mode or moving forward in other modes.
: click button under this symbol to begin moving to Positions 1 in Absolute
Mode or moving backward in other modes.