Function Library
•
83
6.4 Pulse Input / Output Configuration
@ Name
_8132_set_pls_outmode – Set the configuration for pulse command
output.
_8132_set_pls_iptmode – Set the configuration for feedback pulse
input.
_8132_set_cnt_src – Enable/Disable the external feedback pulse
input
@ Description
_8132_set_pls_outmode:
Configure the output modes of command pulse. There are two modes
for command pulse output.
_8132_set_pls_iptmode:
Configure the input modes of external feedback pulse. There are four
types for feedback pulse input. Note that this function makes sense
only when
cnt_src
parameter in
set_cnt_src()
function is enabled.
_8132_set_cnt_src:
If external encoder feedback is available in the system, set the
cnt_src
parameter in this function to
Enabled
state. Then internal
28-bit up/down counter will count according configuration of
set_pls_iptmode()
function.
Or the counter will count the command pulse output.
@ Syntax
C/C++ (DOS, Windows 95/NT)
U16 _8132_set_pls_outmode(I16 axis, I16 pls_outmode)
U16 _8132_set_pls_iptmode(I16 axis, I16 pls_iptmode)
U16 _8132_set_cnt_src(I16 axis, I16 cnt_src)
Visual Basic (Windows 95/NT)
B_8132_set_pls_outmode (ByVal axis As Long, ByVal pls_outmode As
Long) As Integer
B_8132_set_pls_iptmode (ByVal axis As Long, ByVal pls_iptmode As Long)
As Integer
B_8132_set_cnt_src (ByVal axis As Long, ByVal cnt_src As Long) As
Integer
@ Argument
axis
: axis number designated to configure pulse Input/Output.
pls_outmode
: setting of command pulse output mode for OUT and DIR
pins.
pls_outmode=0, OUT/DIR type pulse output.
pls_outmode=1, CW/CCW type pulse output.
pls_iptmode
: setting of encoder feedback pulse input mode for EA and EB
pins.