24
•
Signal Connections
3.8 Deviation Counter Clear Signal ERC
The deviation counter clear signal (ERC) is active in the following 4
situations:
(1) home return is complete;
(2) the end-limit switch is active;
(3) an alarm signal stops OUT and DIR signals;
(4) an emergency stop command is issued by software (operator).
The relative signal name, pin number and axis number are shown in the
following table.
CN2 Pin No
Signal Name
Axis #
8
ERC1
•
26
ERC2
‚
The ERC signal is used to clear the deviation counter of servomotor driver.
The ERC output circuit is in the open collector with maximum 35 V
external power at 50mA driving capability. For more details of the ERC
operation, please refer to section 4.2.3.
35V 50mA Maximum
ERC
From PCL5023
EXGND
Inside PCI-8132