Getting Started
29
NuPRO-A301
4. Connect the CPU fan cable to the CPU fan connector on
the SBC labeled CN1 (see “Board Layout” on page 10).
Note:
Do not use fan/heatsinks
with
push-pin
type attachments.
They may exert too much tension on the PCB and cause the
board to flex, resulting in damage to the SBC.
Holding the SBC with Fan/Heatsink Installed
When the fan/heatsink is installed, always hold the SBC with two
hands by the card edges. Make sure to support the weight of the
fan/heatsink to prevent the board from bending, resulting in dam-
age to circuitry and/or components.
CAUTION:
Failure to properly support the weight of the fan/heatsink
assembly when installed on the SBC may cause the board to
flex and result in damage to circuitry and/or components.