background image

 VBar Pak                                                Safety Precautions

ADJ Products, LLC  -  www.adj.com  - VBar Pak User Manual Page 4

ADJ Products, LLC  -  www.adj.com  - VBar Pak User Manual Page 5

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 21 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

Power Supply:

 The ADJ VBar contains a automatic voltage switch, 

which will auto sense the voltage when it is plugged into the power 

source. With this switch there is no need to worry about the correct 

power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The VBar can be controlled via DMX-512 protocol. The VBar Pak has 8 

DMX channel modes, please see pages 7-8 for the different modes. The 

DMX address is set on the back panel of the VBar. Your unit and your DMX 

controller require a standard 3-pin XLR connector 

for data input and data output (Figure 1). We recom-

mend Accu-Cable DMX cables. If you are making 

your own cables, be sure to use standard 110-120 

Ohm shielded cable (This cable may be purchased 

at almost all pro lighting stores). Your cables should 

be made with a male and female XLR connector on 

either end of the cable. Also remember that DMX 

cable must be daisy chained and cannot be split.

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

 VBar Pak                                                                    Set Up

Figure 1

Содержание VBar Pak

Страница 1: ...ds and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indi rect economic loss associated with the use or reliance of any information contained within this document and or as a result ...

Страница 2: ...when installing the fixture The equipment must be installed by a professional and it must be installed in a place where it is out of the reach of people s grasp VBar Pak Installation VBar Pak Introduction Unpacking Thank you for purchasing the VBar Pak by ADJ Products LLC Every VBar Pak has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping cart...

Страница 3: ...tains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source With this switch there is no need to worry about the correct power voltage this unit can be plugged in anywhere DMX 512 DMX is short for Digital Multiplex This is a universal pro tocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX dat...

Страница 4: ...nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior VBar Pak Set Up DMX512 IN 3 PIN XLR POWER POWER POWER DMX512 DMX DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to co...

Страница 5: ... is displayed you are in Blue dimming mode Press the UP and DOWN buttons to adjust intensity 5 When A XXX is displayed you are in Amber dimming mode Press the UP and DOWN buttons to adjust intensity 6 After you have adjusted the RGBA colors to make your desired color VBar Pak Operating Instructions you can then activate strobing by pressing the SET UP button to enter the Flash strobe mode 7 FS XX ...

Страница 6: ... 1 Plug the fixture in and press the MODE button until CLXX is dis played 2 There are 15 colors to choose from Use the UP and DOWN buttons to scroll through the 15 colors After you have found your desired color you can activate strobing by pressing the SET UP button to enter the Flash strobe mode 3 FS XX will be displayed this is Flash mode The Flash can be adjusted between FS 00 flash off to FS 1...

Страница 7: ...on will activate the strobe effect You can control the flash rate by pressing the and buttons Press this button again to exit strobe mode SPEED Press this button to activate and use the buttons to adjust the speed of color fade and color change mode color fade mode color change mode and the sound sensitivity level DMX MODE This button will let you select which DMX mode you want to use Some fixture...

Страница 8: ...eds Follow the directions below to set your DMX Mode and address 1 Before connecting to an DMX controller your fixture has different DMX channel modes please select your desired mode by press ing the DMX Mode button then using the or buttons to scroll through the DMX Channel Modes See DMX Mode on page 13 2 After you have selected your mode set the DMX address for the fixture by pressing the Set Ad...

Страница 9: ...ar Pak 4 Channel Mode Channels 1 2 3 will not work when Channel 6 is being used Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 5 MASTER DIMMER 0 255 0 100 6 COLOR MACROS 0 255 PLEASE SEE 1 CHANNEL MODE VBar Pak 6 Channel Mode Channels 1 2 3 will not work when Channel 7 is being used Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 ...

Страница 10: ...75 COLOR FADE 11 176 191 COLOR FADE 12 192 207 COLOR FADE 13 208 223 COLOR FADE 14 224 239 COLOR FADE 15 240 255 COLOR FADE 16 SOUND ACTIVE MODE 0 15 SOUND ACTIVE MODE 1 16 31 SOUND ACTIVE MODE 2 VBar Pak 8 Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 5 MASTER DIMMER 0 255 0 100 6 STROBING PROGRAM SPEED SOUND SENSITIVITY 0 15 STRO...

Страница 11: ...e DMX cables are connected properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are connected Unit does not respond to sound 1 Quiet or high pitched sounds will not activate the unit 2 Make sure that Sound Active mode is activated VBar Pak Cleaning Du...

Страница 12: ...nd or improvements upon its products without any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by ADJ Products LLC in connection with this product including warrant...

Отзывы: