Technical manual ADITRAT
11
3.
DISPENSER
3.1.
WORKING CONDITIONS
*
Minimum pressure: 2 bar
*
Maximum pressure: 4 bar
*
Minimum flow: 20 l/h
*
Maximum flow: 1.500 l/h
*
Minimum temperature: 45º C
3.2.
START-UP
Progressively open the water and let the suction pipe fill with
the product to be dispensed. Once the suction pipe is full, the
dispenser will be ready to operate.
3.3.
HOW TO REGULATE THE DOSAGE
Unscrew the dispenser’s body P004.
Pull down the spring.
Take out the pin and place it where you prefer.
Dosage:
. Not use
. 0'5 %
. 0'8 %
. 1 %
Release the spring so that it can go back to its initial position.
Screw the dispenser’s body P004.
3.4.
MAINTENANCE
Respect the flow and pressure values indicated in paragraph 4.
Use the dispenser with cold or tepid water and if the products to be dispensed are solid
take care that they are well dissolved.
Install the dispenser by avoiding sources of heat and frost.
Clean the dispenser every time after using it: make it work and suck clean water at the
same time during 15 minutes.