LCD Error Codes
Installation and Operation
167
60
NO LABEL. The bar code scanner
could not read the bar code label
because there was no label on the
cartridge.
If present, this error appears on the Label Info screen.
If the cartridge does not have a label, place a label on
the cartridge. If the cartridge does have a label,
reposition or replace it. If the error persists, contact
your service provider.
61
READ ERROR. The bar code
scanner could not read the bar code
label because the label was
unreadable.
62
NOT PRESENT. The bar code
scanner could not read the bar code
labels because there was no data
cartridge magazine present.
If present, this error appears on the Label Info screen.
If necessary, install a data cartridge magazine.
65
DMA OVERRUN. The bar code
scanner could not read the bar code
label because a Direct Memory
Access overrun occurred.
If present, this error appears on the Label Info screen.
Make sure the library and tape drives are not being
used by any host, then press
>5HVHW@
on the operator
panel.
If the error persists, contact your service provider.
67
DMA CH. 2 TIMEOUT.
Controller board error.
69
LABEL UPSIDE DOWN. The bar
code scanner could not read the bar
code label because the label is
upside down.
If present, this error appears on the Label Info screen.
Remove the label and reposition it on the cartridge.
If the label is affixed correctly, contact your service
provider.
70
L SERVO TIMEOUT. The CHM
could not reach its destination
along the long axis.
Open the door and look for anything that might be
obstructing the CHM along its long axis.
Make sure the library and tape drives are not being
used by any host, then press
>5HVHW@
on the operator
panel. If the error persists, contact your service
provider.
71
PARAMETER > LIMIT.
Firmware error.
Make sure the library and tape drives are not being
used by any host, then press
>5HVHW@
on the operator
panel.
If the error persists, contact your service provider.
You may be asked to supply a diagnostic listing, and
you may need new firmware.
Error
Description
Corrective Action
Содержание Scalar AIT 440
Страница 1: ...INSTALLATION AND OPERATING GUIDE SCALAR AIT 440 480...
Страница 2: ...Scalar AIT 440 480 Libraries Installation and Operation...
Страница 7: ...vi Scalar AIT 440 480 Notes...
Страница 11: ...x Scalar AIT 440 480 Notes...
Страница 25: ...xxiv Scalar AIT 440 480 Notes...
Страница 101: ...Operating the Tape Drives Installation and Operation 77 Notes...
Страница 135: ...Chapter 8 112 Scalar AIT 440 480 Notes...
Страница 153: ...Chapter 9 130 Scalar AIT 440 480 Notes...
Страница 179: ...Chapter 11 156 Scalar AIT 440 480 Notes...
Страница 185: ...Appendix A 162 Scalar AIT 440 480 Notes...
Страница 195: ...Appendix C 172 Scalar AIT 440 480 Figure C 1 Element indexes for Scalar AIT 440 identical to the element addresses...
Страница 197: ...Appendix C 174 Scalar AIT 440 480 Notes...