background image

   

Industrial

 

Electronic Devices 

 ADFweb.com Srl – IT31010 – Mareno – Treviso 

User Manual   

PROFINET / PROFIBUS Master - Converter 

Document code: MN67604_ENG 

 Revision 1.001   Page 10 of 33

PROFIBUS: 

The  PROFIBUS  uses  a  9-pin  D-SUB  connector.  The  pin  assignment  is  defined 
like in the right figure. 

Here some codes of cables: 

Belden:  p/n  183079A  -  Continuous  Armor  DataBus®  ISA/SP-50 
PROFIBUS Cable. 

PROFINET:

 

The  PROFINET  connection  must  be  made  using  Connector3  and/or  Connector4  of  HD67604-A1  with  at  least  a  Category  5E  cable.  The 
maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 
100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is 
recommended the use of a cross cable. 

Содержание HD67604-A1

Страница 1: ...viceNet Slave www adfweb com Product HD67575 Ethernet www adfweb com Product HD67577 CAN www adfweb com Product HD67579 Modbus TCP Slave www adfweb com Product HD67580 Modbus Slave EtherNet IP from to...

Страница 2: ...ATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recen...

Страница 3: ...etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assemb...

Страница 4: ...Document code MN67604_ENG Revision 1 001 Page 4 of 33 EXAMPLE OF CONNECTION Used with only one PROFINET connection Used like switch it allows to connect a second device to the network without using a...

Страница 5: ...ctronic Devices ADFweb com Srl IT31010 Mareno Treviso User Manual PROFINET PROFIBUS Master Converter Document code MN67604_ENG Revision 1 001 Page 5 of 33 CONNECTION SCHEME Figure 1 Connection scheme...

Страница 6: ...tween PROFINET PROFIBUS PROFINET Power Supply PROFIBUS Power Supply Mountable on 35mm Rail DIN Power Supply 8 24V AC or 12 35V DC Temperature range 40 C to 85 C Up to 1500 bytes from PROFINET to PROFI...

Страница 7: ...cument code MN67604_ENG Revision 1 001 Page 7 of 33 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD676...

Страница 8: ...2 of Dip Switch A The first with Dip2 in Off position factory setting is used for the normal working of the device The second with Dip2 in On position is used for upload the Project Firmware For the o...

Страница 9: ...y slowly 0 5Hz update in progress 3 BF bus fault red ON The Ethernet connection is defective the IP address exists several times in the network the own NameOfStation exists several times in the networ...

Страница 10: ...lden p n 183079A Continuous Armor DataBus ISA SP 50 PROFIBUS Cable PROFINET The PROFINET connection must be made using Connector3 and or Connector4 of HD67604 A1 with at least a Category 5E cable The...

Страница 11: ...IT31010 Mareno Treviso User Manual PROFINET PROFIBUS Master Converter Document code MN67604_ENG Revision 1 001 Page 11 of 33 USB The USB connection must be made with a USB cable with a USB Mini B plug...

Страница 12: ...he Converter use the available software that runs with Windows called SW67604 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to...

Страница 13: ...ire device configuration A device configuration can also be imported or exported To clone the configurations of a programmable PROFINET PROFIBUS Master Converter in order to configure another device i...

Страница 14: ...ROFIBUS are In the field ID Dev the address of the PROFIBUS side is defined In the field Baud rate the baud rate for the PROFIBUS side is defined The means of the fields for PROFINET are In the fields...

Страница 15: ...rk button from the main window for SW67604 Fig 2 the window PROFIBUS Network Management Fig 4 appears In this window is possible to Modify the PROFIBUS Master Options Master PROFIBUS Options Add a PRO...

Страница 16: ...PROFIBUS Options button from the PROFIBUS Network window Fig 4 the PROFIBUS Master Options window appears Fig 5 In this window is possible to set the WatchDog Time for the PROFIBUS Slaves Note Fact1...

Страница 17: ...4 the PROFIBUS Device window appears Fig 6 In this window is possible to Set the PROFIBUS Slave ID ID Slave PROFIBUS Select the Modules present in the PROFIBUS Slave from the Available Modules in GSD...

Страница 18: ...7 Add a Module from the list of GSD file Fig 7 point 6 Remove a Module from selected list Fig 7 point 5 Add all Modules present in the GSD file Fig 7 point 4 Remove all Modules from selected list Fig...

Страница 19: ...dule in hexadecimal The means of the fields are In the field Description of Module a name of the Module is defined In the field Insert the Configuration of Module HEX the configuration of the module i...

Страница 20: ...ossible to insert manually the parameters of Device and also of the Modules Using the Modify User Parameters Manually button is possible to insert modify the parametrization of the device and or modul...

Страница 21: ...y the User and or Modules Parameters manually i e writing the configuration of the parameters in hexadecimal The means of the fields are In the field Insert the number of User Parameter the number of...

Страница 22: ...ed Parameters of module Fig 11 point 2 The Configuration of all parameters in RAW for the Module selected Parameters in RAW Hex Fig 11 point 3 The admited value for the selected parameter It is possib...

Страница 23: ..._ENG Revision 1 001 Page 23 of 33 CAPABILITIES The section Capabilities is used only to show which features baudrates available in the PROFIBUS device The Green Icon indicate that capability baudrate...

Страница 24: ...check it In the field Enable Freeze the PROFIBUS Freeze command is enable This option is enable only if the Freeze Mode is supported by the device see Capabilities section to check it In the field Re...

Страница 25: ...of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A at ON position Turn on the device Connect the Ethernet cable Insert the IP 192 168 2 205 Press the Ping button...

Страница 26: ...rrectly update Note When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67604 A1 device Note When you receive the device for the fi...

Страница 27: ...evices ADFweb com Srl IT31010 Mareno Treviso User Manual PROFINET PROFIBUS Master Converter Document code MN67604_ENG Revision 1 001 Page 27 of 33 MECHANICAL DIMENSIONS Figure 16 Mechanical dimensions...

Страница 28: ...formed by a valid combination of the following HD67604 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67604 PROFINET PROFIBUS Master Conv...

Страница 29: ...3 PLC CONFIGURATION The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal V11 software of Siemens In case o...

Страница 30: ...IT31010 Mareno Treviso User Manual PROFINET PROFIBUS Master Converter Document code MN67604_ENG Revision 1 001 Page 30 of 33 2 Import the module in the network connect the device to the PLC network an...

Страница 31: ...strial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso User Manual PROFINET PROFIBUS Master Converter Document code MN67604_ENG Revision 1 001 Page 31 of 33 3 Load the configuration into the...

Страница 32: ...with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collecti...

Страница 33: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product t...

Отзывы: