background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

RS485 / RS232 / Ethernet

 

 

Document code: MN67038_ENG     Revision 2.003    Page 39 of 42 

 

 
MECHANICAL DIMENSIONS: 

 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Figure 10: Mechanical dimensions scheme for HD67038-xx-A1 

Figure 11: Mechanical dimensions scheme for HD67038-xx-B2 

 

Содержание HD67038-2-A1

Страница 1: ...tion www adfweb com Product HD67038 For Price information www adfweb com Price HD67038 Benefits and Main Features Triple electrical isolation Protocol independent suitable for supervision software Tem...

Страница 2: ...HER REGULATIONS AND STANDARDS 41 WARRANTIES AND TECHNICAL SUPPORT 42 RETURN POLICY 42 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that...

Страница 3: ...vice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Страница 4: ...485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 4 of 42 EXAMPLES OF CONNECTION Note This solution allows also an internet connection of the device so the PC and one or more HD67038 xx...

Страница 5: ...er Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 5 of 42 Note This solution allows also an internet connection of the device so the PC and one or more HD67038 xx A1 HD67038...

Страница 6: ...er Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 6 of 42 Note This solution allows also an internet connection of the device so the PC and one or more HD67038 xx A1 HD67038...

Страница 7: ...Industrial Electronic Devices ADFweb com S r l User Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 7 of 42 CONNECTION SCHEME Figure 1a Connection scheme for HD67038 2 A1...

Страница 8: ...Industrial Electronic Devices ADFweb com S r l User Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 8 of 42 Figure 1b Connection scheme for HD67038 5 A1...

Страница 9: ...Industrial Electronic Devices ADFweb com S r l User Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 9 of 42 Figure 1c Connection scheme for HD67038 4 A1...

Страница 10: ...Industrial Electronic Devices ADFweb com S r l User Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 10 of 42 Figure 1d Connection scheme for HD67038 25 A1...

Страница 11: ...Industrial Electronic Devices ADFweb com S r l User Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 11 of 42 Figure 1e Connection scheme for HD67038 24 A1...

Страница 12: ...Industrial Electronic Devices ADFweb com S r l User Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 12 of 42 Figure 1f Connection scheme for HD67038 2 B2...

Страница 13: ...Industrial Electronic Devices ADFweb com S r l User Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 13 of 42 Figure 1g Connection scheme for HD67038 5 B2...

Страница 14: ...Industrial Electronic Devices ADFweb com S r l User Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 14 of 42 Figure 1h Connection scheme for HD67038 25 B2...

Страница 15: ...between RS232 RS485 RS422 bus and Ethernet bus Mountable on 35mm Rail DIN Auto sensing Ethernet 10 100 Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F...

Страница 16: ...and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device Consumption W VA HD67038 2 A1 B2 3 5 HD67038 5 A1 B2 3 5 HD67038 4 A1 3...

Страница 17: ...ith Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for upload the Project and or Firmware For the operati...

Страница 18: ...ly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet link ON Ethernet cable connected OFF Ethernet cable disconnected ON Ethernet cable connected OFF Ethernet cable...

Страница 19: ...d not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connec...

Страница 20: ...hield Belden p n 82842 2x 24AWG stranded twisted pairs conductor foil shield braid shield Tasker p n C521 1x 24AWG twisted pair conductor foil shield braid shield Tasker p n C522 2x 24AWG twisted pair...

Страница 21: ...uns with Windows called SW67038 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on o...

Страница 22: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable RS485 RS232 Ethernet Converter in order to configure another device in the same manner...

Страница 23: ...he language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to...

Страница 24: ...er from these options Remote COM Port Tunnel Point to Point Tunnel Point to MultiPoint These operating modalities are described in the following pages In the section Select Device field it is possible...

Страница 25: ...serial this field isn t editable it is always checked for the codes with two serials at least one of the two must be checked In the field Port the port used to communicate with converter using TCP UDP...

Страница 26: ...on the fly is checked it is possible to change the baudrate parity and data bits of the serial from an Ethernet command see CHANGE BAUDRATE ON THE FLY section In the field Port the port where addressi...

Страница 27: ...them The window is divided in two section one for Device1 and the other for Device2 It is possible to assign a label to each device in order to have a name to use for understand the project to upload...

Страница 28: ...l line in use is defined In the field Parity the parity of the serial line in use is defined In the field Data Bits the number of data bits used for the serial line communication is defined In the fie...

Страница 29: ...ifferent places Note This modality uses UDP packets The window is divided in two section one for Master device and the other for Slave devices It is possible to assign a label to each device in order...

Страница 30: ...serial line in use is defined In the field Parity the parity of the serial line in use is defined In the field Data Bits the number of data bits used for the serial line communication is defined In t...

Страница 31: ...o section one for Master device and the other for Slave devices It is possible to assign a label to each device in order to have a name to use for understand the project to upload The means of the fie...

Страница 32: ...port of second serial must be different from the first one In the field Socket Disconnect TimeOut Seconds a time in seconds is defined If no data pass through the socket for the seconds defined the s...

Страница 33: ...update the firmware in the device follow these instructions Turn OFF the Device Connect the RS232 Null Modem cable form your PC to the Converter Put Dip2 of Dip Switch A in ON position Select the COM...

Страница 34: ...und must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip2 of...

Страница 35: ...converter try with a native COM port or change the converter Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings Check the Wi Fi settings If...

Страница 36: ...e default value Note You can use this modality only in the Remote COM port modality The packet to send for change these parameters are BAUD baud value PARITY parity value DATABIT parity value serial t...

Страница 37: ...ctor zip After the installation of the software you have to enter in the SW67038 go into the General Parameter section and press the ACTIVE SERIAL DRIVER button At this point it is possible to configu...

Страница 38: ...Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 38 of 42 Go in the Connection prefs Section Step 1 Select the RAW protocol Step 2 Select the Send Keep alive option Step 3 Con...

Страница 39: ...b com S r l User Manual RS485 RS232 Ethernet Document code MN67038_ENG Revision 2 003 Page 39 of 42 MECHANICAL DIMENSIONS Figure 10 Mechanical dimensions scheme for HD67038 xx A1 Figure 11 Mechanical...

Страница 40: ...RS485 on Removable 5mm Screw Terminal connector 24 RS232 on D sub connector type DE 9 Male RS422 on Removable 5mm Screw Terminal connector Device Family HD67038 RS485 RS232 Ethernet Converter Order Co...

Страница 41: ...on systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recyc...

Страница 42: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to t...

Отзывы: