background image

PLUS

Remote Video Unit

Installation and Setup

Guide

K4859  12/99

Содержание RapidEye plus

Страница 1: ...PLUS Remote Video Unit Installation and Setup Guide K4859 12 99...

Страница 2: ......

Страница 3: ...PLUS Remote Video Unit Installation and Setup Guide...

Страница 4: ...Com Corporation The JSC232 485 RS 232 to 485 converter is a product of Javelin Systems Changes or modifications not expressly approved by Ademco could void the user s authority to operate the equipmen...

Страница 5: ...P Address 12 Entering the IP Address 12 3 5 Connecting the Communication Line 15 3 6 Connecting Rapid Eye to the Audio Panel 16 Alarm Inputs 17 Control Outputs 17 4 0 Connecting PTZ Domes 18 4 1 RS 23...

Страница 6: ...roblems 28 C 3 1 Ground Loops and Hum Bars 29 C 3 2 Electrical Interference 29 C 3 3 Recommendations 30 C 4 Backup Power 30 C 4 1 Line Conditioner UPS System 31 Appendix D Configuring Alarm Inputs 32...

Страница 7: ...ser Guide 2 Rapid Eye Remote Video System MANAGER Software User Guide About the Rapid Eye Remote Video System Rapid Eye is an information management quick response video telesurveillance system It is...

Страница 8: ...event has occurred It may be connected to a central monitoring site using PSTN ISDN or Frame Relay This guide describes how to install this unit 2 Rapid Eye OS Operator Software This is a Windows bas...

Страница 9: ...If you see damage to the unit call your designated Ademco representative and describe the problem Please have your Serial Number available the serial number for the Remote Video Unit is located on the...

Страница 10: ...the Rapid Eye PLUS remote video Unit chassis The Remote Video Unit has no customer serviceable items inside and must be returned to Ademco for repair Breaking the factory seals will void your warrant...

Страница 11: ...ectors are used to accept video signals from your CCTV system cameras Depending on the option s ordered the unit might have 4 8 or 16 video input connections Video Mux Out This connector allows you to...

Страница 12: ...alarm signal inputs and the G s refer to the associated ground connection All alarm inputs must be referenced to the ground connection s of the Remote Video Unit Control Outputs These outputs provide...

Страница 13: ...External modem Typically Serial Port 1 PTZ Serial Port 2 RUI for setting LAN Serial Port 1 parameters Passthrough devices Serial Port 2 Note The defaults listed above can be changed by using the RDI f...

Страница 14: ...inue to be captured and stored should power blackouts or brownouts occur The capacity at 300 watts of the UPS should be at least 30 to 60 minutes to allow time for corrective action If a UPS is not us...

Страница 15: ...ween each camera and the Remote Video Unit is 750 feet When installing coaxial cable there must be no loops kinks or wraparounds Avoid running video cables near fluorescent lights RF receivers or tran...

Страница 16: ...the Remote Video Unit is the last or only CCTV device in the series and no other devices are terminating the signal Set the DIP switch to OFF bottom of button pushed in if another CCTV device is alrea...

Страница 17: ...dix D Configuring Alarm Inputs Most alarm sensor units have a dry contact for outputs usually providing type form C outputs both Normal Open and Normal Closed contacts Note which type you have and sel...

Страница 18: ...ector on the CONTROL OUTPUTS terminal strip one wire to ground and the other wire to the numbered connection you choose There must be no bare wire showing at the rear panel when the output control wir...

Страница 19: ...D Full Duplex Null Modem Wiring Diagram 20 RU 20 56 3RUW RUNVWDWLRQ 5HPRWH 9LGHR 8QLW Figure 5 Null Modem Cable Connection 2 Start a Terminal program such as Windows Hyper Terminal In Windows 95 selec...

Страница 20: ...3 0 Installing the Remote Video Unit Figure 6 Connection Description dialog box 4 In the Connect To dialog box select the Workstation s COM port number to which the null modem cable is attached in th...

Страница 21: ...er an IP address for example set ipaddr 172 16 2 38 10 Enter a sub net mask for example set subnet 255 255 0 0 11 Enter a router address for example set router 172 16 1 1 Note To verify a parameter ty...

Страница 22: ...left of terminal strip Output 7 DATA IN Output 8 CLK Output 8 Ground GND second from left of terminal strip Table 1 RAS Panel to Rapid Eye Cable Connections Any type of telephone or data communicatio...

Страница 23: ...s 1 Attach alarm 16 input to the TRIP connection on the audio panel terminal strip 2 Attach alarm input 16 ground to the first GND from the left connection on the audio panel terminal strip Control Ou...

Страница 24: ...Note There is a support limit of one type of PTZ per Remote Video Unit The installation procedure consists of installing the PTZ units followed by connection to the RS 232 485 Converter and the Rapid...

Страница 25: ...D 312 computer interface The PTZ domes are generally connected to RS 232 Port 2 and must be configured using the Operator software NOTE The address of the dome must match the camera input number on th...

Страница 26: ...te at its default communication baud rate Kalatel and Javelin units are set at 9600 bps Pelco D Protocol units are set at 2400 bps and P Protocol units are set to 4800 bps Each dome must be set to the...

Страница 27: ...nit is now ready to capture store and transmit fast response full color images to process and transmit alarm information and to control external devices An Operator System refer to the Rapid Eye Remot...

Страница 28: ...Rapid Eye Remote Video Unit Installation and Setup Guide 22 6 0 Powering Down the Remote Video Unit false alarms when you initially set up the Rapid Eye PLUS remote video Unit...

Страница 29: ...he following information ready when you call your service center so that we may better assist you Your name company name and address Contact telephone number Whether you are connecting to the Rapid Ey...

Страница 30: ...on is also useful for your own records when making changes to the camera type description or system configuration values Rapid Eye Remote Site Information Site Name ________________________ Location _...

Страница 31: ...ined not by the camera A CCTV system must also have a means to record events that can later be used for training or as evidence C 1 Lighting Characteristics The lighting at the scene determines the am...

Страница 32: ...00 Storage rooms warehouses inactive indoor 5 50 Storage yards outdoor 1 20 10 200 Parking open medium activity outdoor 1 2 10 20 Parking covered medium activity outdoor 5 50 Parking entrances day nig...

Страница 33: ...r at each end are used C 2 1 Connectors The BNC connector is commonly used for CCTV connections because of its small size ease of twist on installation and low signal loss The three types of BNC conne...

Страница 34: ...lection of the signal resulting in distortion For outdoor applications ensure all connectors are weatherproof If unbalanced coaxial cable runs exist between low power sources use fiber optic cable to...

Страница 35: ...synchronization signal Caution Do not attempt to solve any of the above problems by removing the third wire on a three prong electrical plug This is a violation of local electrical codes and the Unde...

Страница 36: ...cables carrying low level signals Each signal line should have its own independent return line running as close as possible to the signal line C 4 Backup Power It is important to consider how possible...

Страница 37: ...onstant voltage ferro resonant transformer and line sensing circuitry to regulate power When the incoming power is stable the UPS transformer cleans up the raw line power eliminating spikes dips surge...

Страница 38: ...RDI in the Advanced Configuration window The Remote RDI window is displayed Figure 12 Remote RDI Window 3 Enter a command from one of the following sections Enabling the Alarm Input Type 1 Click the d...

Страница 39: ...Rapid Eye Remote Video Unit Installation and Setup Guide Appendix D Full Duplex Null Modem Wiring Diagram 33 Appendix D Full Duplex Null Modem Wiring Diagram...

Страница 40: ...CCTV Practices 24 Communication Line Connecting 15 Connecting Cameras 9 21 Comunication Line 15 Connectors 26 Control Outputs 6 Converter PTZ 19 D Daisy chain Multiple Domes 20 DIP Switches 5 9 Domes...

Страница 41: ...lems Cameras 27 PTZ Cables 20 Connecting Domes 18 RS 232 Converter 19 R Rear Panel Connectors 5 Related Documents 1 Remote Site Information 23 Remote User Interface RUI using 12 RS 232 7 RS 232 Conver...

Страница 42: ......

Страница 43: ...165 Eileen Way Syosset NY 11791 Copyright 1999 PITTWAY CORPORATION l K4859 12 99...

Отзывы: