When cascading AdderView MATRIX keep in mind the following rules
The maximum number of layers in a AdderView MATRIX cascade is four.
You may cascade MATRIX units with 1 or 2 KVM links. The number of KVM links
that you install defines the number of simultaneous uses that are supported.
Keep all cascade cables as short as possible. The video quality is maximised by
using the shortest possible total cable run from computer to KVM.
If you are making multiple cascade links between AdderView MATRIX then
ensure that the cables are approximately the same length.
AdderView OSD devices may be cascaded to MATRIX cascades but the OSD
units must always be on the lowest level of the cascade (in other words you must
not cascade a MATRIX device off an OSD device)
AdderView 208 and 216 models may be cascaded together.
You must choose groups of cascade ports from the following table. When you
cascade using a group of ports the system will allocate the first available free port in
that group (see section 4.10 and 4.15 for more details)