6243/44 DC Voltage Current Source/Monitor Operation Manual
2.1.3 Rear Panel Summary
2-8
1. Output terminal section (only 6243)
OUTPUT
terminals (
HI and LO
):Voltage and current output terminals
SENSE
terminals (
HI and LO
):Voltage output terminals in the remote sense mode (4-wire connec-
tion) and current measurement input terminals
DRIVING GUARD
terminal: Driving guard output terminal (of Guards the HI side connection
while at the same potential as that of the HI SENSE terminal)
2. AC power connector:
Connects the 6243/44 to the AC power supply through this connec-
tor with the supplied power cable.
3. Voltage selector, fuse holder:
Allows the voltage setting to be switched manually to match the
used AC line voltage. A fuse is contained inside the holder.
4.
GP-IB
connector:
Used for connecting the 6243/44 to an external controller with a
GPIB cable.
5.
INTERLOCK OPERATE IN/OUT
connector:
Interlock Connector used to operate the ON/OFF input signal, or the
ON/OFF output signal.
At TTL level open drain output, the output is pulled up to +5 V with
10 K
.
For input, the input impedance is approximately 10 K
and for out-
put, the output impedance is approximately100
.
6.
COMPLETE OUT BUSY IN/OUT
connector:
Connector used to output the measurement completion signal, and
the I/O signal while the measurement is in progress (busy).
The completion signal is a negative pulse. The pulse width depends
on the setting (20
s to 30
s or 100
s to 200
s) of the pulse width
at the external control signal output.
At the TTL level open drain output, the output is pulled up to +5 V
with 10 K
.
For input, the input impedance is approximately 10 K
and for out-
put, the output impedance is approximately 100
.
7.
SYNC OUT
connector:
Output connector used to output the signal synchronized with the
pulse and sweep source value output.
At the TTL level open drain output, the output is pulled up to +5 V
with 10 K
. The output signal is a negative pulse. The pulse width
depends on the setting (20
s to 30
s or 100
s to 200
s) of the
pulse width of the external control signal output. The output imped-
ance is approximately 100
.
WARNING:
A hazardous voltage is output if conditions such as the following occur: the instrument is
damaged, an external hazardous voltage is applied, or relevant setting conditions occur.
Be careful of electric shocks.
WARNING:
A hazardous voltage is output if an external hazardous voltage is applied to the case, causing
a potential difference between the case and the LO.
!