Provisioning
LTPH-TP-1044-01, Issue 1
26
April 6, 2001
HXU-358 V1.04
Cross Connecting
The HXU-358 cross-connect feature allows the grooming of any of the T1/E1
channels to any time-slot location within the high speed DS3 frame. For
additional information about the Digital Access Cross-Connecting Switch
(DACS), see
“Time-slot Assignment Switch (TSA)” on page 57
Figure 15.
Config Menu: X-Connect
To change a time-slot, first make sure that the time-slot that you want to
change is available (not in use by another port). If the time-slot is unavailable
(used on another port), place both the time-slot that you want and the
time-slot in use by another port in the NO-CONNECT settings.
1
Select T1/E1 Ports from the Config menu.
2
Change the port’s Srvc Mode to MEM-ADMIN by pressing the
, and then press
.
3
Select X-Connect from the Config menu.
4
Change the port’s Timeslot setting of the time-slot that you want to NO
CONNECT by pressing the
, and then press
.
Main Monitor History
Config
Test Inventory Quit Help
+-------------------+
| T1/E1 Ports |
| DS3 Port +---------------------------------------+
| Password | Port Timeslot | Port Timeslot |
| Date and Time| 1
1 - 1
| 15 4 - 3 |
| Card ID | 2 1 - 2 | 16 4 - 4 |
| SW Download | 3 1 - 3 | 17 5 - 1 |
|
X-Connect
| 4 1 - 4 | 18 5 - 2 |
| Autologout Ti| 5 2 - 1 | 19 5 - 3P
|
| Maintenance P| 6 2 - 2 | 20 PROTECTION |
| Circuit IDs
| 7 2 - 3 | 21 6 - 1 |
| Restore Defau| 8 2 - 4 | 22 6 - 2 |
+--------------| 9 3 - 1 | 23 6 - 3 |
| 10 3 - 2 | 24
DOWN
|
| 11 3 - 3 | 25 7 - 1 |
| 12 3 - 4 | 26 7 - 2 |
| 13 4 - 1 | 27 7 - 3 |
| 14 4 - 2 | 28 7 - 4 |
+---------------------------------------+
Use <Spacebar> to cycle through option settings and <Enter> to activate
ID: | Card 'A' 03/30/01 10:47:02 ALARMS: NONE
SPACEBAR
ENTER
SPACEBAR
ENTER