background image

 
 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

Signature Series

 

L-860 and L-860E Elevated LED  
Low-Intensity Elevated Edge Light (ELIL)  

 

 

 

Document No. 96A0388 

Issued: June 4, 2008 
Rev. B: June 23, 2009 
 
 

 

 

ETL Certified to L-860 AC 150/5345-46C 
and FAA Engineering Brief No. 67B.  Meets 
ICAO: Annex 14, Vol. 1, para. 5.3.5 for use on  
a non-precision instrument runway

 

 

 

 

 

 

ADB Airfield Solutions 

 

 

 

Copyright 

©

 2008 by ADB Airfield Solutions   All rights reserved. 

 
 

 

 

 

 

Содержание L-860

Страница 1: ...ment No 96A0388 Issued June 4 2008 Rev B June 23 2009 ETL Certified to L 860 AC 150 5345 46C and FAA Engineering Brief No 67B Meets ICAO Annex 14 Vol 1 para 5 3 5 for use on a non precision instrument runway ADB Airfield Solutions Copyright 2008 by ADB Airfield Solutions All rights reserved ...

Страница 2: ...ld Solutions 96A0388B Page ii All rights reserved Issued 6 08 Page Rev Description EC No Checked Approved Date All A Released new manual 1976 1991 ER ER 6 16 08 parts B Update ordering codes parts specs and diagrams to include red and green 2350 JG ER 7 07 09 Record of Changes ...

Страница 3: ...scription 2 1 1 Introduction 2 1 2 L 860 LED Elevated Light Fixture Required Equipment 2 2 3 Specifications 2 3 Input 2 3 Expected LED Life 2 3 Light Source 2 3 Environmental Operating Conditions 2 3 Weight 2 4 Photometric Data 2 4 Section 3 Installation 3 1 1 Introduction 3 1 2 Unpacking 3 1 3 Placement 3 1 4 Installation 3 2 Base Mounting 3 2 Section 4 Maintenance 4 1 1 Introduction 4 1 2 Mainte...

Страница 4: ...e Ordering Code 7 2 Figure 7 2 ELIL L860 Elevated LED Fixture Parts 7 4 Table 2 1 Mounting Columns 2 2 Table 2 2 Required Equipment Supplied 2 2 Table 2 3 Required Equipment Not Supplied 2 3 Table 2 4 Power Requirements 2 3 Table 2 5 Light Fixture Weight 2 4 Table 2 6 L860 Photometric Data 2 4 Table 4 1 L 860 Light Fixture Maintenance 4 1 Table 7 1 Numerical Recommended Spare Parts List 7 3 List o...

Страница 5: ...ation set forth above but in no event less than 12 months from repair or replacement In the case of any other breach of the foregoing warranty Seller shall furnish engineering services or specialized tools equipment and instruments to the same extent as on the original work Buyer shall grant Seller access to the goods or services at all reasonable times in order for Seller to determine any nonconf...

Страница 6: ...hout obligation of ADB Airfield Solutions to notify any person of such revision or change Details and values given in this manual are average values and have been compiled with care They are not binding however and ADB Airfield Solutions disclaims any liability for damages or detriments suffered as a result of reliance on the information given herein or the use of products processes or equipment t...

Страница 7: ...ns and touching any parts Refer to FAA Advisory Circular AC 150 5340 26 read and become familiar with the general safety instructions provided in this section of the manual before installing operating maintaining or repairing this equipment read and carefully follow the instructions given throughout this manual for performing specific tasks and working with specific equipment store this manual wit...

Страница 8: ...is the responsibility of the company operating this equipment to see that its personnel meet these requirements WARNING Use of this equipment in ways other than described in this manual may result in personal injury death or property and equipment damage Use this equipment only as described in this manual ADB Airfield Solutions cannot be responsible for injuries or damages resulting from nonstanda...

Страница 9: ...l to install ADB Airfield Solutions and auxiliary equipment Use only approved equipment Using unapproved equipment in an approved system may void agency approvals Make sure all equipment is rated and approved for the environment in which you are using it Follow all instructions for installing components and accessories Install all electrical connections to local code Use only electrical wire of su...

Страница 10: ... water is present Use this equipment only in the environments for which it is rated Do not operate this equipment in humid flammable or explosive environments unless it has been rated for safe operation in these environments Never touch exposed electrical connections on equipment while the power is ON Do not operate a system that contains malfunctioning components If a component malfunctions turn ...

Страница 11: ... Solutions replacement parts Using unapproved parts or making unapproved modifications to equipment may void agency approvals and create safety hazards Check interlock systems periodically to ensure their effectiveness Do not attempt to service electrical equipment if standing water is present Use caution when servicing electrical equipment in a high humidity environment Use tools with insulated h...

Страница 12: ...d lights are ETL certified according to FAA specification AC 150 5345 46C and FAA LED specifications per FAA Engineering Brief 67B The ELIL also meets the requirements for ICAO Annex 14 Vol 1 para 5 3 5 for use on a non precision instrument runway The ELIL can be supplied with or without a heater arctic kit NOTE Signature Series is a trademark of ADB Airfield Solutions Figure 2 1 L 860 ELIL FAA El...

Страница 13: ...hub Base mounting is recommended because maintenance is easier to perform The mounting column is available in three standard lengths Refer to Table 2 1 NOTE The measurements in Table 2 1 are taken from the grade to the top of the light fixture Table 2 1 Mounting Columns Type Overall Mounting Height inches mm Standard FAA minimum 14 355 6 Standard 24 610 Standard FAA maximum 30 762 Refer to Table 2...

Страница 14: ...e 2 4 Power Requirements For a Power Source Voltage parallel circuit w o heater 95Vac min to 264Vac max 50 60Hz Voltage parallel circuit w heater arctic kit 120Vac 10 50 60Hz Fixture Load ELIL Fixture Power Fixture Load w o heater 95 264Vac 7W 14VA w heater arctic kit 120Vac 22W 29VA See Table 2 4 Up to 100 000 hours 3 Watt high lumen density brightness white LED 1 Watt high brightness Red and Gre...

Страница 15: ...eight 14 Inch overall height 5 lb 2 27 kg 24 Inch overall height 6 25 lb 2 84 kg 30 Inch overall height 7 lb 3 18 kg Table 2 6 L860 Photometric Data Measured Peak Intensity candelas Color Light Source 2 10 Degrees Vertical Minimum White FAA Omni directional side emitting LED 50 15 FAA White ICAO Omni directional side emitting LED 55 15 ICAO Red Omni directional side emitting LED N A N A Green Omni...

Страница 16: ...detection of equipment damage If you note any damage to any equipment file a claim with the carrier immediately The carrier may need to inspect the equipment This subsection describes the placement of the L 860 light fixtures Follow the guidelines below along with FAA specification AC 150 5340 30 and site plans when placing the L 860 light fixture The L 860 light fixture is normally positioned a m...

Страница 17: ...ll the L 867 base on undisturbed soil If the soil is unsuitable remove soil to an adequate depth and replace with compacted acceptable material NOTE In closed duct systems install in soil conditions with good drainage Use light bases having a drain hole to prevent water accumulation 2 Orient the cable entrance hubs of the light base in the proper direction according to site plans 3 Level the light...

Страница 18: ...el circuit wires Also meg each parallel circuit wire with respect to each other and with respect to earth ground 10 Bolt the base plate with the base plate gasket to the L 867 base using six 3 8 16 stainless steel bolts Apply a drop of Loctite number 243 to each bolt thread and use a torque wrench to torque bolts down to 100 110 inch pounds 11 3 Nt m Level the light fixture only after mounting it ...

Страница 19: ...el and align Clean weep holes Annually Check for improper ground elevation Check for improper light elevation Check for corrosion present or paint loose or chipped Check for chipped paint on exterior body and fixture Check gaskets seal for leakage Grade so frangible point is approximately 1 inch 25 4 mm above ground elevation Maintain same elevation for all light fixtures Scrape and repaint Touch ...

Страница 20: ...parts for repair or maintenance purposes To assemble parts perform the following procedure 1 See Figure 7 2 and repair replace components in Section 6 starting on page 6 1 Also see Parts List and recommend Spare Parts List in Section 7 NOTE Apply a light coat of anti seize compound on the locking ring threads to make assembly and disassembly easier 2 Insert the wiring through the column and the fr...

Страница 21: ...ures for the L 860 LED elevated light Problem Possible Cause Corrective Action 1 LED not lighting Defective electronic module Loose wire connections Deteriorated wire insulation or voltage too low Moisture present in fixture Replace the electronic module Tighten wire connections Replace wires or correct input voltage Open and dry the fixture Inspect the glassware for cracks Replace the electronic ...

Страница 22: ...et and the Glassware Assembly CAUTION The LED arctic kit and electronic module are not repairable Failed items can only be replaced CAUTION When servicing the internal components do not loosen and remove the screws that hold the glassware in place To remove the glassware assembly simply grasp the collar below the glassware and turn counter clockwise and unscrew the assembly off of the housing Acce...

Страница 23: ...assembly The cordset will fit through the clearance hole in the housing If replacement is necessary see Spare Parts List in Section 7 3 Separate the disconnect between the electronic module and the transformer cordset assembly NOTE The Cordset is connected to the terminal block located at the bottom of the PCB Assembly 1 If the Transformer or the Cordset must be removed replaced Remove the LED and...

Страница 24: ...ipping it up and off of the glassware 3 If glassware is broken or cracked discard and install new glassware When installing new glassware also replace the o ring seal at the same time 4 After the o ring has been installed on the top of the Locking Ring place glassware on top of the o ring and then slip the Lens Attachment Ring with the beveled edge of the hole over the glassware 5 Align the holes ...

Страница 25: ...d Solutions part number The Description column gives the part name as well as its dimensions and other characteristics when appropriate Indentions show the relationships between assemblies subassemblies and parts Part Number Description Quantity Note xxxxxxxx Assembly 1 A xxxxxxxx Part 1 xxxxxxxx Part or Assembly xxxxxxxx Assembly 1 NOTE A The Quantity column contains the quantity required per uni...

Страница 26: ...UPLING 2 24 OAH WITH 1 1 2 COUPLING 3 30 OAH WITH 1 1 2 COUPLING 4 14 OAH WITH 2 COUPLING 5 24 OAH WITH 2 COUPLING 6 30 OAH WITH 2 COUPLING LED COLOR 1 WHITE OMNI FOR FAA 2 WHITE OMNI FOR ICAO 11 TPI COUPLING 3 RED GREEN BI DIRECTIONAL 4 RED OMNI DIRECTIONAL 5 GREEN OBSCURED UNI DIRECTIONAL ELIL X X X X 0 1 When powered by a parallel circuit heater is designed for use at only 120Vac 10 50 60Hz Fig...

Страница 27: ...T 1 S 61A0350 NS Frangible Coupling 2 inch w 2 11 TPI ICAO only 1 S 62A0007 2 NS Column for 14 inch OAH for 2 inch coupling 1 A S 62A0007 3 7 2 Column for 14 inch OAH for 1 1 2 coupling 1 A S 62A0007 13 NS Column for 24 inch OAH for 1 1 2 2 inch coupling 1 A S 62A0007 19 NS Column for 30 inch OAH for 1 12 coupling 1 A S 62B0073 7 2 Frangible Coupling 1 1 2 12 UNF 1 S 62A2155 3 2 1 Locking Ring Whi...

Страница 28: ...ECTIONAL and UNI DIRECTIONAL ASSEMBLY SHOWN Orient glassware assembly integral to led lamp color assembly of LED mount EXAMPLE 1 Red glass with red LED EXAMPLE 2 Green glass with green LED obscured glass with no LED OMNI DIRECTIONAL ASSEMBLY SHOWN 64A0957 06 6 32 PAN HD PHIL W CAPTURED EXT STAR WASHER 67A0033 THERMAL JOINT COMPOUND 67A0048 ANTI SEIZE COMPOUND RM0512 POLYESTER FILM TAPE Note 1 Equi...

Страница 29: ...Light Parts 2008 Siemens Airfield Solutions 96A0388B Page 7 5 All rights reserved Issued 6 08 2 13 9 LOCKING RING PROVIDED WITH CORD SET GREEN WIRE E BLUE WIRE N BROWN WIRE L 3 L N E Figure 7 3 ELIL L860 Elevated LED Fixture PCB Wiring ...