AM.04.510e - Edition 1.5
30
Troubleshooting
6
Troubleshooting
6.1
Troubleshooting guide
Table: 6.1
Troubleshooting guide
Problem
Possible cause
Possible solution
No light or light flickers
Connection to the input power
has a malfunction.
-
Remove the fixture. See
§ 4.4.
-
Check the electrical
connection, the cable
and the receptacles.
The LED has a malfunction
Replace the optical assy.
See § 5.2.4.
Connection of the optical assy to
the PCB has a malfunction.
-
Remove the optical
assy. See § 5.2.4.
-
Check the electrical
connections and the
cable.
The PCB has a malfunction
Replace the inner cover assy.
See § 5.2.5.
Light output too low
The prism is dirty.
Clean the prism.
The LED has a malfunction.
Replace the optical assy.
See § 5.2.4.
The PCB has a malfunction.
Replace the inner cover assy.
See § 5.2.5.