AM.04.510e - Edition 1.5
28
Maintenance
Disassemble
1.
Remove the fuse resistor(s) (A) by pulling
the legs of the fuse resistor.
2.
Dispose of the old fuse resistor.
3.
Take the new fuse resistor from the kit.
4.
Place the new fuse resistor in the socket.
Assemble
1.
Insert the legs of the new fuse resistor in the socket.
5.3
Waterproof test
Tools
-
Air hose with dry air
-
Water container with water
-
Waterproof test adapter (tool A). See § 7.5.
Connect
1.
Connect the air hose (A) to the waterproof
test adapter (B).
2.
Connect the waterproof test adapter to the
hole of the pressure release valve (C).
3.
Apply 20 to 30 kPa (0.2 - 0.3 Bar) over
pressure on the air hose.
Test
1.
Submerge the fixture in water and turn
regularly.
2.
If you still see a stream of bubbles (A) after
three minutes of submersion there is a leak.
3.
Remove the fixture from the water.
4.
Disconnect the waterproof test adapter.
5.
Dry the fixture.
A
A
B
C
A
A