29
AM.04.510e - Edition 1.5
Maintenance
In case of a leak
1.
Locate the leak source.
2.
Replace the gasket or part that causes the leak.
3.
Repeat the waterproof test.
5.4
Fixture operation test
Tools
-
FAA or IEC series transformer, powered from a FAA or IEC constant current generator
1.
Connect the fixture to the transformer
2.
At this moment, do not connect a remote communication unit between the fixture and the
transformer.
3.
Set the step of the constant current generator to 6.6 A.
4.
Check if the light works properly for 10 s.
5.
Turn OFF the constant current generator.
6.
If the fixture did not work or has switched off before the end of the test time, see § 6.1.
Note
Also check contact surfaces for any scratches, corrosion or other damage.
Note
The power of the series transformer shall not exceed 200 W, for versions with the
monitoring option.