P a g e 7
Issue 002
Fresnel and PC lens Spotlights
1000, 1200 & 2000 W
Vertical Adjustment
On both arms of the yoke, two sets of holes (70 mm apart) allow higher or
lower positioning of the luminaire (a curved yoke is available as an option).
• Unscrew the two nuts (n°5) with a 17 mm socket or tubular wrench.
• Remove the metal washers (n°4 and n°3).
• Unscrew completely the locking handle (n°6) and remove the washer
(n°10).
• Remove the yoke from the guide blocks by spreading the two arms,
then remove the round-headed screw (n°9).
• Reposition the yoke in the guide blocks corresponding to the selected
height and follow the reversed procedure for re-assembly.
Longitudinal Adjustment
The yoke can traverse the length of the unit allowing the luminaire to be
balanced in any position.
• Partly unscrew the two nuts (n°5) with a 17 mm socket or tubular
wrench.
• Slide the yoke in the desired position and tighten the nuts.
Focus Adjustment
This luminaire features an adjustment knob (ref. 14) allowing to control
focusing and to adjust the beam diameter.
Cleaning the Mirror and the Lense
• Unplug power supply and open the access door to the lamphouse
(ref. 1 - page 12), remove the reflector,the lamp and the lenses.
• Clean the reflector and the lenses with a clean and soft cloth soaked
in alcohol.
• Mount the lamp, mount and tighten the reflector and the lenses.
Installation
This luminaire can be suspended from a barrel by means of A20, A25,
A30 or DIN 15560-24 hookclamps; it can also be mounted on a stand
(these accessories are available as options).
• Avoid installing the luminaire near inflammable matters.
Minimum distance between luminaire and inflammable matters is
indicated on the identification plate (pt 10 - page 10).
• Stay within the maximum tilt angles allowed as indicated on the
indentification plate (pt. 15 - page 10).
• In accordance with safety regulations, always use a safety cable run
in the anchorage ring.
Accessories
The filterframe cassette is equipped with:
• a slide for a wire mesh safety guard
• to slide for accessories of :
- 185 x 185 mm (DIN15560) for 1 kW and 1.2 kW spotlights
- 245 x 245 mm (DIN15560) for 2 kW spotlights
• a doorlock
Remark:
The weight of the accessories shall not be more than 25% of the weight
of the luminair.
Colour Scroller
Hook the mounting plate of the colour scroller onto the upper part of
the filterframe cassette; then hinge down the colour scroller against the
cassette until the spring snaps onto the luminaire.
Use the colour scroller safety cable run in the anchorage ring of the
luminaire.
1 locking disk
2 distance tube
3 friction washer
4 DIN 127A washer
5 M10 DIN 934 stainless
steel nut
6 locking handle
7 yoke
8 guide block
9 round-headed square neck
screw
10 DIN 125A Ø10 washer
1 access door to lamp house
2 tilt locking handle
3 anchorage ring for safety
cable
4 yoke runner
5 identification plate
6 yoke fixation nut
7 yoke
8 doorlock for accessories
9 filter frame cassette
10 wire mesh front lens safety
guard
11 handle
12 stirrup for power supply plug
13 power supply socket
14 focus control
2
3
4
5
6
7
10
9
8
1
13
14
11
12