Advanced Control Equipment (ACE2)
96A0357 Rev. F
Introduction
© ADB Airfield Solutions All Rights Reserved
18
— Time the CCR has been on Step 4 xH4.
— Time the CCR has been on Step 5 xH5.
— Total number of the CCR OFF-ON switching cycles xC.
NOTE:
Small x = time in hours.
Pushbutton 3
, Select/Config, becomes active and is used only in a stand-alone L-827 or
L-829 mode of operation, described above in Pushbutton 2.
Pushbutton 4
, Software Version, initiates the automatic sequence displaying the following
system parameters:
— Main Control Board Firmware Version.
— Lamps-Out Monitor Firmware Version.
— IRMS Firmware Version.
— RS422 channel A network address.
— RS422 channel A baud rate.
— RS422 channel B network address
— RS422 channel B baud rate.
Appearance of question marks instead of the firmware version number means the firmware is
not loaded for that function.