To keep the light fixtures operating efficiently, follow a preventive maintenance schedule. Refer to
. Refer to FAA AC
150/5340-26 for more detailed information.
Table 1: Preventive Maintenance
Interval
Check
Corrective Action
Daily
Low light output
Clean outer surface of prism if dirty. Refer to Cleaning Light Channel
and Lens this section.
Check for presence of moisture in fixture.
Weekly
For obstruction in light output
channel
Clean the optical surface. Refer to
Monthly (or more frequently
during rainy seasons)
For presence of moisture or water
(visual inspection for
condensation on inner side of
prisms)
Open up light assembly.
Clean, dry, and inspect light assembly.
Replace cover/inner cover gasket and other parts found defective.
Replace LED assembly. Refer to
.
Bimonthly
Torque on hold-down bolts
Torque two bolts holding fixture to base. Refer to Torquing Mounting
Bolts in this section. Refer also to Installation on L-828B Base in the
Installation section.
Semi-annually (or more
frequently during rainy seasons)
Check the base for water ingress
Remove water from base.
Remove and inspect light for water damage.
After snow removal
For damaged light fixtures
Replace damaged fixtures.
Use a power broom for snow removal, if practical.
6.4 Workshop Maintenance
Remember
Before you start, make sure you have read and understand
.
Important
Make sure you check the fixture for watertightness very time you replaced a spare part!
The following standard tools and accessories are required for maintenance of the unit:
•
One angled socket spanner of 16 or 17 mm
•
One torque limiting spanner with 16 or 17 mm socket
•
Torx screw driver 10, 20, 25, and 30 mm
•
Two large flat blade screwdrivers
•
CC-Patron grease
•
One brush or cloth
•
Non-alcohol based cleaner
•
Water-tightness tool
NOTICE
A compressor, or a manual car tire pump, equipped with a manometer is required to check the light fixture for water-
tightness.
Design may differ from picture depending on application. Please follow described work flow and torque level specified
as they are generic.
1
Depending on type and size of nuts and bolts
RELIANCE Omni 1-Dome,
Maintenance
20
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE Omni 1-Dome
Страница 1: ...RELIANCE Omni 1 Dome 8 inch User Manual UM 5073 Rev 1 0 2021 07 13 ...
Страница 2: ......
Страница 8: ...RELIANCE Omni 1 Dome List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 10: ...RELIANCE Omni 1 Dome List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 20: ...RELIANCE Omni 1 Dome General Information 10 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 26: ...RELIANCE Omni 1 Dome Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 28: ...RELIANCE Omni 1 Dome Operation 18 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 52: ...RELIANCE Omni 1 Dome Maintenance 42 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 54: ...RELIANCE Omni 1 Dome Troubleshooting 44 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 60: ...RELIANCE Omni 1 Dome POWER TABLE 50 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 62: ...RELIANCE Omni 1 Dome CABLE LOSS 52 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 66: ......