![ADB Safegate RELIANCE Omni 1-Dome Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/adb-safegate/reliance-omni-1-dome/reliance-omni-1-dome_user-manual_2847420023.webp)
•
The minimum thread engagement into top flange of base is 12,7 mm (0.5 inch).
•
As required to ma0/ through -1/16
‑
inch below grade FAA installation tolerance, a maximum of three spacer rings
may be stacked together.
1. Carefully clean all contact surfaces of the light fixture and the base.
2. Put the correct gasket (0-ring or labyrinth gasket) on the inner cover of the light. Refer to the
appendix
for this fixture.
3. Connect the connector of the light fixture to the base supply cable.
4. Place the connector under the light fixture and install on the base.
5. For an installation on bases, use a torque limiting box spanner of 16/17 mm, install and tighten the two fixing bolts or nuts
to a torque value according to specification, refer to
appendix. For other base manufacturers, refer to
their specifications.
Restriction
Do not use high speed for tightening, the recommended speed is 10
‑
40 rpm.
6. After installation, check that each light fixture functions properly.
7. In order to bond the light fixture to ground, use the supplied screw (Torx M4×6 mm, Torque 2.5 Nm) to attach the braided
ground strap to the grounding point on the light fixture. The grounding point is indicated by a grounding symbol and
located on the bottom side.
Removing the fitting from the base
CAUTION
Fall- and trip hazard! When a light fixture has been removed, the base must be fitted with a cover designed for this
purpose or with a spare light fixture.
1. Remove the light fixture from the base using two large flat blade screwdrivers.
2. Disconnect the secondary supply connector.
3. Remove and check the gasket (O-ring or labyrinth).
Note
It is recommended to change the gasket, lock nuts or bolts each time the light fixture is removed or dismounted from
the base. For more information, refer to
appendix.
CAUTION
Use of incorrect combination of gaskets, bolts and nuts can create severe damages to the product installation and
create multiple safety risks.
Make sure to know what base the light fixture will be installed in, in order to chose the correct gasket, bolts and nuts.
Failure to follow these cautions can result in equipment damage or aircraft FOD. For more information, see
4.6 Installation on a Shallow Base
Installing the RELIANCE omnidirectional light fixture on a shallow base involves preparing the pavement recess and wire ways,
then installing the light fixture on a shallow base.
Note
Refer to
section for additional details on the optional shallow base supplied with the
RELIANCE omni fixture.
UM-5073, Rev. 1.0, 2021/07/13
13
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE Omni 1-Dome
Страница 1: ...RELIANCE Omni 1 Dome 8 inch User Manual UM 5073 Rev 1 0 2021 07 13 ...
Страница 2: ......
Страница 8: ...RELIANCE Omni 1 Dome List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 10: ...RELIANCE Omni 1 Dome List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 20: ...RELIANCE Omni 1 Dome General Information 10 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 26: ...RELIANCE Omni 1 Dome Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 28: ...RELIANCE Omni 1 Dome Operation 18 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 52: ...RELIANCE Omni 1 Dome Maintenance 42 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 54: ...RELIANCE Omni 1 Dome Troubleshooting 44 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 60: ...RELIANCE Omni 1 Dome POWER TABLE 50 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 62: ...RELIANCE Omni 1 Dome CABLE LOSS 52 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 66: ......