GB
45
8) Signal lamps and warning sounds
Signal
Mode
Status
Power
Green lamp
OFF
No power supply to ADAX SET
ON
Power supply to ADAX SET is OK
GSM
Blue lamp
OFF
No SIM-card
Invalid SIM-card
SIM-card PIN-code not deactivated
Main power switch in OFF position
Flashing
Searching for network, receiving or transmitting SMS
ON
Coupled to GSM network
Output
Red lamp
ON
ADAX SET’s power output ON
OFF
ADAX SET’s power output OFF
Warning sound
(Default OFF)
Warning sounds may be
activated/deactivated by SMS
One “BEEP”
Status is changed
Many “BEEPS”
Power supply disconnected
Long “BEEP”
ADAX SET has connected to GSM network
ADAX SET is successfully returned to the default settings
9) For your safety:
• ADAX SET is designed for indoor use. ADAX SET must not be used
for industrial or professional purposes. ADAX SET must not be used
in areas with a lot of dust, moisture or chemicals, or in other detri-
mental conditions.
• Appliances connected to ADAX SET must be rated at 220–240 Volts
and maximum 16 Amps. The maximum recommended power con-
sumption is 3000 Watts.
• Before use, the GSM signal at the situation of use must be checked
to ensure it is strong enough. The ADAX SET cannot be regarded as
reliable if the signal is weak.
• The housing (except for the cover marked “SIM”) must be opened by
authorized personnel only.
• ADAX SET must not be exposed to intense shaking, hard knocks or
falls.
• ADAX SET is a GSM product with a wireless signal and must not be
used in areas where electric appliances might interfere with it or be
interfered by its radio signals.