GB
39
2) User access and command codes:
ADAX SET’s functions may be controlled by the APP or by SMS com-
mands. User access has two levels: One Master User and an unlimited
number of Extra users.
Master User:
Only the Master User has access to all of ADAX SET’s functions. The
Master User may be changed by entering a new telephone number via the
APP or by SMS command (see the table, page 41 for the SMS command).
The Master User always receives a message when extra users send com-
mands to ADAX SET.
Extra user:
An unlimited number of Extra users may operate ADAX SET. Extra
users have access to the ON/OFF function and the automatic temperature
control. If extra users attempt to employ other commands they will be
refused with an SMS: “Sorry, you are not authorized to use this com-
mand.” Extra users who employ the APP must know and use the code that
the Master User entered during first time registration, to register ADAX
SET on their phones. Extra users who use SMS must, in addition to the
SMS code, type the code that the Master User entered during first time
registration (see table page 41).
The code must be a four digit number. The default is:
1234
and is changed
during the registration of the Master User.
NB! ADAX SET sends an SMS confirmation of a successful or
unsuccessful command. Refer to point 12, page 47 and 48, to see the
reasons if confirmation is not received.
NB! All settings stored in ADAX SET are retained even if the power
is disconnected.
3) The M button functions:
• ADAX SET is switched ON and OFF by holding the M button in for one
second. If ADAX SET is ON, it will be switched OFF, and vice versa.
• ADAX SET reverts to the default settings if the M button is held in
for 15 seconds. Reverting to the default settings may also be carried
out via the APP or by SMS.