2016.05.16
Adaptrum©
P a g e
46 | 64
All Rights Reserved Worldwide
2016
Adaptrum ACRS2.0 Quick Start Guide (International)
Database Tab
BASE
For units configured for “manual database” (as shown in field #9 below), this tab is unused. However, it
is recommended that users fill in fields #2, 3, and 4 for future use. For units configured in other
database modes, required fields depend upon the spectrum oversight agency.
Figure 27: GUI screenshot: BASE Database tab
Note: Fields in gray font are reserved for Adaptrum diagnostic use.
#
FIELD
DESCRIPTION
1
Device Info
device ID, Serial Number, and Mode hardcoded into hardware
2
Device Location
Latitude/Longitude/Height of installed unit to be entered by user
3
Contact info
name, address, phone number;
may be required by spectrum oversight authority
4
Registrant info
name, address, phone number;
may be required by spectrum oversight authority
5
Register Device
sends Contact and Registrant info to cognizant spectrum oversight agency
6
Device Info/Loc
same as field #1
7
Update Interval
number of seconds between updates (Device & Channel fields #6 & #7)
8
Hold Channel
requires unit to retain channel even after timeout
9
Database
specifies database source for constraining available channel list [1]
10 BASE MAC
address (initially blank; updated by button #14)
11 BASE Channel List
list of channels selected by button #15 (initially blank, updated by button #14)
12 CLIENT MAC
address (initially blank; updated by button #14)
13 CLIENT Channel List
list of channels selected by button #16 (initially blank, updated by button #14)
14 Reset Channel Req
resets current channel selection (enables selection of a new channel set)
15 Base DB
[manual database only] opens Station Channel List for BASE channel selection
16 Client DB
[manual database only] opens CLIENT Channel List for CLIENT channel selection
Table 9: BASE Database Field Descriptions
[1] Units are typically shipped configured for a specific region as constrained by the database indicated in field #9
above. In example Figure 27, this unit is unconstrained (by “manual database” mode).
A