2016.05.16
Adaptrum©
P a g e
45 | 64
All Rights Reserved Worldwide
2016
Adaptrum ACRS2.0 Quick Start Guide (International)
Diagnostics Tab
This tab is used to measure channel quality of either all or just the selected channels. The screenshot
below is an example of Measure All.
Figure 26: GUI screenshot: Diagnostics tab
#
FIELD
DESCRIPTION
1 Channel ID
channel number
2 Channel Quality
a measure of quality predicated upon Noise and Interference; lower is better
3 Channel List
list of available channels constrained by Database tab field #9
4 Measure Available
initiate quality measurement of selected available channels (field #3)
5 Measure All
initiate quality measurement of all channels
Table 8: Diagnostics Field Descriptions
Channel Quality is indicated numerically (lower numbers are better) and by color bars, interpreted as
follows:
Green
Good
Yellow
Marginal
Orange
Avoid (NOT recommended)
Red
Bad (do NOT use)
Channel Selection: When selecting a channel, chose the one with the best Channel Quality and, if
possible, with good quality adjacent channels as well.
A
P
P
EN
D
IX