Replacing a Fan Module
Snap Server 700i Series
2
Field Service Documentation
Copyright © 2007, Adaptec, Inc. All rights reserved. Information in this document is subject to change without notice and does not represent
a commitment on the part of Adaptec or any of its subsidiaries.
2
With both thumbs, press the buttons on the top of the cover, then slide the cover
off of the rear of the server and set it aside.
Removing a Failed Fan Module
The Snap Server 700i has two types of fans: Chassis fans (Fan 1 and Fan 5) and CPU
fans (Fan 2 and Fan 3).
1
Determine which fan has failed.
a
Launch Adaptec Storage Manager.
b
In the Enterprise view, click the server with the fan problem, then right-click
the Enclosure Management Device to the right of the disk icons.
c
In the Properties window that opens, click the Status tab. You will see a list of
all the fans with a yellow or red exclamation point next to the problem fan.
Click
server
Right-click
device