ADAM-6022 

Dual Loop PID Controller 

User’s Manual 

Содержание ADAM-6022

Страница 1: ...ADAM 6022 Dual Loop PID Controller User s Manual...

Страница 2: ...s product in applications that required particular safety or when using this product in important facility pay attention to the safety of the overall system and equipment For example install fail safe...

Страница 3: ...erate ADAM 6022 utility software can help you to select input and range configuration set the operating parameter SP Sv Pv etc for your process control needed ADAM 6022 utility software also integrate...

Страница 4: ...20mA and 4 20mA The analog output channel is 12 bit with 0 10V 0 20mA and 4 20mA acceptable input type Each analog channel is allowed to configure an individual range for several applications The dig...

Страница 5: ...Application Wiring Fig 7 2 Analog Input Output Wiring Diagram Fig 7 3 Digital Input Wiring Diagram...

Страница 6: ...page The website is simply the IP address of the ADAM 6022 module you want to connect For example http 172 18 3 24 Before you open the web page you need to type correct user name and password Below i...

Страница 7: ...Jumper Setting The Backup SRAM jumper default setting is Disable Please set the jumper in Enable when using ADAM 6022 I Current Signal V Voltage Signal Input Default V Output Default I...

Страница 8: ...gh the network Clicking the 6022 in the system tree of left dialog block Clicking the 6022 in the system tree of left dialog block to go to ADAM 6022 configuration page In this page user can configure...

Страница 9: ...an see the detail MODBUS address register number for each channel in this page It can be a very important reference for communication work ADAM 6022 input channel configuration also support Zero and S...

Страница 10: ......

Страница 11: ...ty software ADAM 6022 can be a pure universal I O module when PID being set in Free mode User can use Data Area to setup the analog output to send a specific value for such kind application This funct...

Страница 12: ......

Страница 13: ...lues changing of SV PV and MV It is very helpful for user to monitor and diagnose the PID control situation For the functionality of the bottom in PID configuration page please refer the explanation o...

Страница 14: ...e setting bottom to go to the detail parameter setting screen PV SV Setting Bottom Function Input channel for PV selection For Loop 0 PV set 0 or 1 For Loop 1 PV set 3 or 4 Formula Selection Standard...

Страница 15: ...larm High SV PV High alarm setpoint Alarm Low SV PV Low Low alarm setpoint Alarm L Low SV PV Low alarm setpoint MV Setting Bottom Function Control Action Mode Setting Direct Direct Heating Action Reve...

Страница 16: ...d shutdown For PID parameter tuning please refer the PID tuning page In this page the P I D parameters can be adjusted to achieve the optimal control result The real time trend chart provide a powerfu...

Страница 17: ...tput will be set to startup value 01 OK 01 error aaDcc Read the channel startup output value 01hhh hhh is value in HEX scaled range from 000 to FFF 01 error aaDcchhh Set the channel startup output val...

Страница 18: ...aa3cchhh Calibrate the analog output to correct the MIN error cc channel 00 01 01 OK 01 error aa5mm Enable Disable multiplexing 01 OK 01 error aa6 Asks a specified input module to return the status o...

Страница 19: ...01 error aaMASK Read subnet mask 01mmmmmmmm 01 error aaGW Read default gateway 01mmmmmmmm 01 error aaDEVNAME Read device name 01sssssss 01 error aaDEVDESC Read device description 01 ssssss 01 error...

Страница 20: ...trol ADAM 6022 will be a pure I O module 1 PID mode enable PID loop function 2 Manual mode manual control analog output 41002 41258 PID Mode Read Write 0 PID Mode Selection 0 Standard PID Calculation...

Страница 21: ...41284 Range High PV Source 2 Read Write 3 PV Source 2 Engineering Value Range High Range High Range Low 41030 41286 Range Low PV Source 2 Read Write 3 PV Source 2 Engineering Value Range Low Range Lo...

Страница 22: ...1316 MV Range Code Read Only 0 0 0 10V 1 0 20mA 2 4 20mA 41062 41318 PID KP PV Source 1 Read Write 3 PID Proportional factor for PV Source 1 PID KP Input value 1000 41064 41320 PID KI PV Source 1 Read...

Страница 23: ...ec 41092 41348 OLD NSEC Read Only 0 Calculating the previous Loop interval as old nsec 41094 41350 Power recovery action setting Read Write 0 0 maintaining the previous MV output and keep PID open 1 S...

Страница 24: ...it PV Source 2 Read Write 3 Alarm Low Limit Value for PV Source 2 RL Alarm LL 41122 41378 Alarm Dead Band PV Source 2 Read Write 3 Dead band for PV Source 2 0 Input Value 1000 10 41124 41380 Alarm Sta...

Страница 25: ...mode z The MV will output the MV Emergency Value z The DO will switch to ON as an Alarm 41150 41406 PID Direct Reverse Read Write 0 0 Direct Mode 1 Reverse Mode 41152 41408 SV High Limit PV Source 1 R...

Страница 26: ...ing 1 Coils Address Mapping Table Index Address Remarks 1 0 DI 0 status 2 1 DI 1 status 3 16 2 15 Reserved for those reserved area there will be no effect if you set it 17 16 DO 0 status 18 17 DO 1 st...

Страница 27: ...ort 1000 1511 999 1510 PID data area total 512 registers z Each PID data formed by two registers for example PID data 0 reg 1000 65536 reg 1001 z In the Appendix C if the Decimal Place is 3 which mean...