FIRST USE AND UNIQUE MACHINE CODE
The device has been designed to always stay ON if powered; each having its own machine
number set to 0 as default. When the manager presents its MASTER card at first use, the de-
vice will register its machine number inside the software. This machine code will be unique
and will be used to configure the user TAG keys that are part of that system and that can
only be used with that system. For this reason, if user TAG has to be used with multiple de-
vices, it is critical to use only one MASTER card to configure these multiple devices, giving
so to all of them the same machine code. Once installation is complete, it is recommended to
calibrate the meter for better accuracy (
see calibration paragraph
). It will also be necessary to
program the user TAG keys to authorize refuelling (see dedicated paragraphs). Remove the
transparent protection on meter display.
MASTER FUNCTIONS
Starting from “partial” screen, proceed with
to enter in MASTER mode. Approaching
the MASTER card, the systems sounds Beep (3 times) and the screen “Prog” appears. In this
mode, button allows to go to next function while button confirms the selection. The
succession of screens pressing each time the button is as follows:
1) CANCEL TOTALS, with preceding message “CLRTOT”
2) TRANSACTION PRESELECTION, with preceding message “PRESET”
3) PERIOD PRESELECTION, with preceding message “PREPER”
4) PROGRAM TAG, with preceding message “TAGSET”
5) AUTHORIZE/BLOCK TAG, with preceding message “LOCHED”
6) UNIT OF MEASURE, with preceding message “UNIT”
7) CALIBRATION, with preceding message “CAL”
8) SETTING PARAMETERS, with preceding message “SETPAR”
9) EXIT, with preceding message “EXIT”
21
AF 3000 - AF 3000 TAG