6. MAINTENANCE
GENERALPROVISIONS
It is recommended to stop and take action with the extraordinary maintenance whenever a not
optimal operation is detected; this will allow always having the maximum efficiency.
Always use the special P.P.E. - Personal Protective Equipment:
• Gloves
• Non-slip shoes
• Goggles
• Mask
• Suitable clothing
Cleaning of the filter
4. EXTRAORDINARY MAINTENANCE
Programmed Maintenance Table:
MAINTENANCE
TIMELINE
STATE OF THE MACHINE
SYMBOL
Every 3 months
Isolation for Maintenance
Check/cleaning of
litre counter filter
non compliance of what is requested, exempts the manufacturer from
any liability to the effects of the guarantee.
make sure that the pump is disconnected from the electrical current
and that it is not in operation
1. unscrew the screws that hold tight the front part of the metal sheet and open the distributor;
1
2
3
41
AF 3000 - AF 3000 TAG