HCB-J JEWELLERY SERIES 

 

(P.N. 308660002 Revision A, June 2012)

 

Software 3.7  

 

 

 

 

 

 

Содержание HCB-J Jewellery Series

Страница 1: ... Adam Equipment Company 2012 Adam Equipment HCB J JEWELLERY SERIES P N 308660002 Revision A June 2012 Software 3 7 ...

Страница 2: ...ERATURE PARAMETERS 14 6 2 ALLOY PARAMETERS 15 7 0 PARAMETERS 16 7 1 ENABLING WEIGHING UNITS F1 Unt 17 7 2 HOLD FUNCTION F2 Hld 19 7 3 BACKLIGHT F3 bL 20 7 4 PRINTING PARAMETERS F4 Ser 20 7 5 AUTO POWER OFF F5 OFF 22 7 6 INTERNAL OR EXTERNAL CALIBRATION F6 ICE 22 7 7 ADJUST THE VALUE OF THE INTERNAL MASS F7 CA 23 7 8 USER TECHNICAL PARAMETERS F8 SEt 24 8 0 USER CALIBRATION 25 9 0 SERIAL INTERFACE S...

Страница 3: ...echargeable battery HandiCalTM calibration backlit display and ShockProtectTM with overload indicator With the RS 232 interface for communication with printers and computers splash proof keypad and sturdy plastic construction the HCB J will be a balance you can rely upon We hope that you enjoy using your new balance 2 0 SET UP 2 1 UNPACKING AND SETTING UP YOUR BALANCE 1 Remove the balance and all ...

Страница 4: ... cable running down the back of the balance 4 Lift the beaker away to the rear and locate the Density Chamber support into the receptacle with the arrow facing the rear of the balance Press gently to insert it then secure the support in the center using the M4 x 20mm screw which is packed in the accessory bag Tighten only enough to secure the pan support so that it does not rock in the receptacle ...

Страница 5: ...oose amount of cable 6 Place the Density Chamber over the beaker with the handle of the lid at the front and allowing for the sample pan to hang freely inside it Secure the Chamber to the support by rotating it gently clockwise and locking into the 3 tabs Take care not to push down or use excessive force on the Chamber when fixing as damage can be caused ...

Страница 6: ...ghtly pulled down through the clip and that it does not interfere or sit close to the Density Chamber or Chamber support If the cable is touching against any of these parts it will result in incorrect weighing and karat calculations Position the balance and Remote Indicator in a convenient place and adjust the feet to show a level state Switch on the balance whilst using battery power or connect t...

Страница 7: ...ier Care should be taken to not spill any liquid onto or inside the balance as damage may occur which is not covered under the normal warranty terms To fill the beaker whilst it is away from the balance it will be necessary to remove the Temperature Sensor and clip from the beaker which then allows it to be removed from the support The cable will need to be pulled gently upwards from below the Tem...

Страница 8: ...results to the interface When setting some parameters this key will move the flashing digit to the right Unit Clr Pressing this key will cycle through the weighing units which are enabled When in density mode pressing the Unit Clr will return the display to normal weighing mode Density Pressing after the weight in the air and in the liquid have been stored will show the density and karat results W...

Страница 9: ...ately 24 hours with the backlight off Depending on the usage of the backlight the lifetime of the battery will reduce and using the remote display will lessen the battery life considerably The display will show an indication when the battery needs to be charged To charge the battery plug the adapter into the POWER socket at the back of the balance and connect it to the mains power supply The charg...

Страница 10: ...elding equipment or large motors Do not let the balance battery go flat If you are not using it for a long time you should charge the battery periodically to make sure the battery does not lose its charge Keep free from vibration Do not place near heavy or vibrating machinery Avoid high humidity that might cause condensation Keep away from direct contact with water Do not spray or immerse the bala...

Страница 11: ...d show a zero reading This may be necessary if the weight reading is not indicating zero with nothing on the pan The zero indicator will show up in the upper left corner of the LCD If you are using a container whilst weighing then you can place this on the weighing pan and press the Tare key Providing the container weight is more than 4 of the maximum capacity of the balance the display will show ...

Страница 12: ...splay will show HOLD If the Hold function is set to automatic you are not required to press the Hold Print key once the weighing in air becomes stable After the Hold symbol is shown press the Air Liquid key to store this value Wait for the Weight in Air indicator to be displayed before you proceed to the next step Remove the sample and ensure the balance returns to zero If necessary press the Tare...

Страница 13: ... sample weight requirements when the message ADD is being displayed the balance will continue to calculate based on the sample weight at that time 5 2 DISPLAY DENSITY Press the Density key to display the density of the sample ie 14 2 den Press the Density key a second time to display the Karat value for the sample For example if gold with silver is selected the display would show 14 KAg Like wise ...

Страница 14: ...0 1000 13 64 13 47 13 80 12 22 12 04 12 40 12 89 12 71 13 06 13K 542 1000 13 98 13 81 14 15 12 61 12 41 12 80 13 26 13 07 13 44 14K 584 1000 14 34 14 16 14 52 13 02 12 81 13 22 13 65 13 45 13 84 15K 625 1000 14 72 14 53 14 91 13 46 13 23 13 68 14 06 13 85 14 27 16K 667 1000 15 12 14 92 15 32 13 93 13 69 14 16 14 50 14 28 14 72 17K 708 1000 15 54 15 33 15 75 14 43 14 17 14 69 14 97 14 73 15 20 18K ...

Страница 15: ... Liquid to view the Alloy parameters When Alloy is displayed press Tare to enter this section or press Air Liquid to return to the Liquid parameters 6 1 LIQUID AND TEMPERATURE PARAMETERS The parameters available are water H2O and any other user definable liquid If water is used and selected the next parameter will ask to determine the temperature of the water selections are either using the automa...

Страница 16: ...e correct value is shown The display will return to show Liquid Press Unit Clr to return to weighing or press air Liquid or Density to change the display to set the Alloy parameters 6 2 ALLOY PARAMETERS The balance will compute the density based on the mass and weight values recorded The value for purity karats and content will be computed depending on the alloy selected by the user The alloy opti...

Страница 17: ...ser FUNCTION SECTION DESCRIPTION F1 Unt See section 7 1 Sets the units to be used g ct GN dwt oZt Oz Lb MM t tLH tLS tLT tLJ F2 HLd See section 7 2 Sets the operation of the Hold function On HD Manual hold the weight whit the Hold Print key Auto HD Weight held automatically when stable OFF HD Hold function Off Density function disabled F3 bL See section 7 3 Sets the backlight on BL backlight alway...

Страница 18: ...turn to normal weighing or press Air Liquid to go to the next function 4 When F1 Unt is displayed you can press the Tare key to view the current setting for the weighing units 5 Press Unit Clr at any time to return to the parameter heading 6 Pressing the Hold Print key will cycle through the other units along with their current settings For example if oFF is displayed with the weighing unit Carats...

Страница 19: ...of a silver penny in medieval England Equals to 1 20th of an Ounce Troy 0 6430149 dwt Ounce Troy Troy ounce used for weighing gold silver and in pharmacy 0 03215075 oZt Ounce Avoirdupois ounce 16 ounces make a pound 0 035274 oZ Pounds Standard weighing unit in UK USA 0 0022046 Lb Mommes A weighing unit used in Japan to weigh pearls 0 266667 MM Tola An Asian weighing unit 0 085735 t Taels Hk Hong K...

Страница 20: ...rate The Hold Print key will function only as a print key On Hd Sets the hold function to be on when the user presses the Hold Print key 1 Switch on the balance then press and hold the Unit Clr key during the self checking test of the display 2 After a few seconds the display will show the first function F1 UNT 3 Press the Air Liquid key to select F2 Hld 4 Press the Tare key to view the current se...

Страница 21: ...st function F1 UNT 3 Press the Air Liquid key to select F3 bL 3 Press the Tare key to view the current settings for the backlight 4 To change the setting press the Air Liquid key to scroll through and select a new setting as shown above 5 Press Tare to confirm and move to the next setting 6 When F4 Ser is displayed press the Tare key to enter the parameter the Unit Clr key to return to weighing or...

Страница 22: ...ll send the data again Press the Air Liquid key to change the setting Press Tare to confirm and move to the next setting 6 Setting the baud rate This is the transmission speed for communication with printers and computers The selected rate must match that of the other device for communications to work The following settings are available 2400 bPS 4800 bPS 9600 bPS 7 Press the Air Liquid key to cha...

Страница 23: ...isplayed press the Tare key to enter the parameter the Unit Clr key to return to weighing or press Air Liquid to go to the next function 7 6 INTERNAL OR EXTERNAL CALIBRATION F6 F6 F6 F6 I I I ICE CE CE CE You can select to use the internal mass or an external mass to calibrate the balance 1 Switch on the balance then press and hold the Unit Clr key during the self checking test of the display 2 Af...

Страница 24: ...he flashing digit position press the Hold Print key Press the Air Liquid key to increase the value or the Density key to decrease the value The internal calibration weight should only change between 95 00 and 105 00 grams or 495 00 and 505 00 grams depending upon the model 6 Press Tare to confirm and move to the next setting 7 When F8 SEt is displayed press the Tare key to enter the parameter the ...

Страница 25: ...Switch on the balance then press and hold the Unit Clr key during the self checking test of the display 2 After a few seconds the display will show the first function F1 UNT 3 Keep pressing the Air Liquid key until F8 SET is displayed 4 Press the Tare key to view the current setting 5 To change the settings press the Air Liquid key Press the Tare key to store the setting and advance to the next pa...

Страница 26: ...e the handle is pushed to the side which will lower the calibration mass Internal Calibration using HandiCal 1 Press and hold the Air Liquid and Density keys at the same time and power on the balance 2 Release both keys when the display shows unload 3 Remove any weight from the pan assembly and press the Tare key when the stable sign is shown 4 The display will show C Int Press the Tare key and th...

Страница 27: ...n be used are as follows Model HCB J302 HCB J1002 HCB J2002 Weight 1 100g 500g 500g Weight 2 200g 700g 1000g Weight 3 300g 1000g 2000g 6 Once the calibration weight has been selected press the Tare key 7 The display shows LoAd Place your weight on the pan Press the Tare key after the stable sign is shown 8 The display will show PASS if the calibration is successful 9 Remove the weight and the disp...

Страница 28: ... of data are printed including one blank line at the end Note the Karat unit should reflect the setting of the Alloy parameters K Ag K Cu K 1 1 K m n or Ko Def If the density is of a value that does not allow the karat value to be determined the printout should have blank values for content and karat For example Sample WT air 54 00 g cr lf Sample WT liquid 50 00 g cr lf Liquid Density 0 997 g cm3 ...

Страница 29: ...y test If sent whilst displaying the density results it will cause the density report to be printed as above If the Hold Function F2 HLD is Off the command will only print the weight readings A cr lf When the weight is Held on the display this command will store the weight in memory for either weight in air or weight in liquid the same as if the Air Liquid key is pressed U cr lf Acts in the same w...

Страница 30: ...ng the remote display 11 0 TEMPERATURE SENSOR During the density test if the balance has been set to use the auto temperature sensor it must be plugged into the balance Turn the balance off Plug the temperature sensor into the 5 pin circular connector on the rear of the balance Turn the balance back on and the sensor will now work automatically If the sensor becomes unplugged the display will show...

Страница 31: ...lectronics damaged Remove any weight from the stainless steel pan and turn the balance off and back on again Try calibrating the balance Err 9 A D count is not stable when turning the balance on Load cell damage Something touching the pan Air movement vibration or instability There may be movement vibration or dirt on the balance during turning on Make sure there is nothing touching the pan Make s...

Страница 32: ...apter USA plug 12VDC 800mA 3 02 4 0 9156 AC adapter UK plug 12VDC 800mA 3 02 4 0 9157 AC adapter Euro plug 12VDC 800mA 3 02 4 0 9158 AC adapter SA plug 12VDC 800mA 3 02 4 0 9159 AC adapter Australian plug 12VDC 800mA 3 08 0 0 2043 Beaker 3 08 1 2 2045 Beaker Support 3 08 1 2 2046 Density Chamber 3 08 1 2 2047 Sample Pan 3 08 1 2 2048 Sample Pan Suspension Hook 3 08 0 0 2044 Temperature Sensor 3 08...

Страница 33: ... Lb MM t tLH tLS tLT tLJ 13 2 COMMON SPECIFICATIONS Communication Interface RS 232 Stabilisation Time 2 Seconds typical Operating Temperature 0 C to 40 C 32 F to 104 F Power supply external 12VDC 800 mA Calibration HandiCal Internal calibration or external calibration User selectable Display 18mm high 6 digit LCD Auto backlight and capacity tracker Balance Housing ABS Plastic with Density Determin...

Страница 34: ...nal packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements...

Страница 35: ...in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to ope...

Страница 36: ...Health and Fitness Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technol...