53 © Adam Equipment Company 2011
Switch off the indicator, and switch it on again to continue with the other Service
parameters.
16.2.2
F2–DECIMAL POINT POSITION
To set the value for the decimal point location. The options are 0, 0.0, 0.00,
0.000, 0.0000
To enter this parameter, press the
[Tare]
key when
“F2 dEC”
is shown.
The display will show the current setting.
Press the
[Func]
key to change the value. Select from 0, 0.0, 0.00, 0.000, 0.0000
Press
[Tare]
to accept the displayed value.
16.2.3
F3 – CAPACITY
To enter this parameter, press the
[Tare]
key when
“F3 CAP”
is shown.
The display will show the current capacity.
Enter the numeric values using the keypad. The indicator will check the number of
divisions n = maximum/increment is less than 30,000 divisions. (3000 divisions for
EC approved versions)
Press
[Tare]
to accept the displayed value.
On non-approved versions the display then lets you select the increment,
“InC 2”
For example 100kg x 0.01kg the increment is 10grams. but the last digit increments
by 1.