background image

EN • 2

ENGLISH

FRANCAIS

NEDERLANDS

ESP

AÑOL

IT

ALIANO

DEUTSCH

664Y2900.C

WARNINGS 3

Who should read these instructions 

3

Symbols 2
Applicable standards 

2

Recommendations 2
Warnings 2

DESCRIPTION 3

Packing 3
Technical characteristics 

3

Hydraulic connections 

3

Dimensions 3

INDEX

Essential instruction for the safety of persons
and the environment.

Danger of electrocution.

Essential instruction for the correct operation of
the installation.

WHO SHOULD READ THESE INSTRUCTIONS

These instructions should be read by:
- the specifying engineer
- the installer
- the user
- the service engineer

SYMBOLS

The following symbols are used in this manual:

• The product must be installed and serviced by trained

engineers, in compliance with current standards.

• Any failure to follow instructions relating to tests and test 

procedures may result in personal injury or risks of pollution.

•  To guarantee safe and correct operation of the appliance, it 

is important to have it serviced and maintained every year by 
an approved installer or maintenance company.

•  In case of anomaly, please call your service engineer.

• Despite the strict quality standards imposed by ACV during 

the manufacture, inspection and transport of its appliances, 
you might notice some errors. Please report immediately any 
fault to your approved installer.

•  The parts may only be replaced by genuine factory parts. You 

will find a list of the spare parts and their ACV reference 
number at the end of this document.

WARNINGS

This documentation is part of the information delivered with the
appliance and must be given to the user and stored in a safe
place!

An approved installer must carry out the assembly, commissioning, 
maintenance and repair of the system, in accordance with current 
standards in force.

ACV shall not accept any responsibility for damage caused by 
non-compliant location of the system or by use of the parts or 
connections not approved by ACV for this application.

  The manufacturer reserves the right to change the 

technical characteristics and specification of its
products without notice.

 

The availability of some versions and their accessories 
is market dependant..

WARNINGS

ELECTRICAL CONNECTION 

4

HeatMaster 201: serial number > at 1000 

4

HeatMaster 201: serial number < at 1000 

4

HeatMaster 200N 

6

BOOSTER KIT ASSEMBLY 

7

APPLICABLE STANDARDS

The appliances carry the 

CE

 mark in accordance with the

standards in force in the various countries (European Directives 

92/42/EC

 “Efficiency”, 

90/396/EC

 “Gas appliances”).

They also carry the “

HR Top

” label (Gas boilers).

RECOMMENDATIONS

 

• Please, carefully read this manual before installing and

commissioning the boiler.

•  It is prohibited to carry out any modifications to the inside of 

the appliance without the manufacturer’s prior and written 
agreement.

Содержание HeatMaster 200N Booster

Страница 1: ...EN 1 ENGLISH FRANCAIS NEDERLANDS ESPA OL ITALIANO DEUTSCH 664Y2900 C Assembling and installation instructions HeatMaster 201 Booster HeatMaster 200N Gas Booster HeatMaster...

Страница 2: ...your approved installer The parts may only be replaced by genuine factory parts You will find a list of the spare parts and their ACV reference number at the end of this document WARNINGS This docume...

Страница 3: ...he 4 ways valve Pack 6 Booster kit including the Booster bracket and holder tubes and hydraulic components for the heating and shunt loops Pack 7 Gas burner with insulation and gasket only HeatMaster...

Страница 4: ...nnect the ground to 19 Connect the brown wire to 20 closing contact Connect the blue wire to 21 neutral Connect the black wire to 22 Opening contact Booster shunt pump 19 Connect the line connection o...

Страница 5: ...20 Connect the ground to 16 Connect the brown wire to 17 closing contact Connect the blue wire to 18 neutral Connect the black wire to 19 Opening contact Booster shunt pump 19 Connect the line connect...

Страница 6: ...common of the relay 18 Connect the neutral of the Booster shunt pump 19 to terminal 10 Connect the hot line of the Booster shunt pump 19 to the normally closed terminal of the relay 18 1 2 3 4 5 6 7...

Страница 7: ...parts from the rear panel 7 Fix the Booster holder on the mounting legs with four M10 bolts 4 Put the rear panel in place 5 Mount the two M M union connections on the flow and the return of the boile...

Страница 8: ...justment 10 Mount a 90 elbow on the lower nipple of the Booster 11 On this elbow mount the 2 tube with the two right hand threads Pay attention to the threads one tube has a left hand thread 12 On thi...

Страница 9: ...nion connexion 19 Connect the shunt pump with its upper and lower tube between the HeatMaster and the Booster 20 Mount the 6 studs on the flange and put the gasket in place 21 Locate the flue collecto...

Страница 10: ...H 664Y2900 C BOOSTER KIT ASSEMBLY 24 Hydraulic connexion of the heating system 25 Electric connexion of the shunt pump M5 see pages 4 5 and 6 26 Commissioning of the system and control of the complete...

Отзывы: