BOOSTER KIT ASSEMBLY

9.  - Place the back right side panel.
 

- Connect the the upper tube of the Booster shunt loop.

13.  Mount the second  2” tube 

with the left hand thread 
on the coupling. Leave 
some threads for later 
adjustment.

10. Mount a 90° elbow on the 

lower nipple of the Booster.

11. On this elbow, mount the  

2" tube with the two right-
hand threads.

 

Pay attention to the 

threads : one tube has a 
left-hand thread.

12. On this 2" tube, mount the 

left hand and right hand 
threaded coupling; screw 
it half-way to leave the 
adjustment.

14.  Mount the 90° elbow on the 

2”tube.

15.  Mount the third 2” tube 

with  the 90° elbow and the 
union connexion.

16.  Ensure that the union 

connection is aligned with 
the 4-ways valve.

Содержание HeatMaster 200N Booster

Страница 1: ...EN 1 ENGLISH FRANCAIS NEDERLANDS ESPA OL ITALIANO DEUTSCH 664Y2900 C Assembling and installation instructions HeatMaster 201 Booster HeatMaster 200N Gas Booster HeatMaster...

Страница 2: ...your approved installer The parts may only be replaced by genuine factory parts You will find a list of the spare parts and their ACV reference number at the end of this document WARNINGS This docume...

Страница 3: ...he 4 ways valve Pack 6 Booster kit including the Booster bracket and holder tubes and hydraulic components for the heating and shunt loops Pack 7 Gas burner with insulation and gasket only HeatMaster...

Страница 4: ...nnect the ground to 19 Connect the brown wire to 20 closing contact Connect the blue wire to 21 neutral Connect the black wire to 22 Opening contact Booster shunt pump 19 Connect the line connection o...

Страница 5: ...20 Connect the ground to 16 Connect the brown wire to 17 closing contact Connect the blue wire to 18 neutral Connect the black wire to 19 Opening contact Booster shunt pump 19 Connect the line connect...

Страница 6: ...common of the relay 18 Connect the neutral of the Booster shunt pump 19 to terminal 10 Connect the hot line of the Booster shunt pump 19 to the normally closed terminal of the relay 18 1 2 3 4 5 6 7...

Страница 7: ...parts from the rear panel 7 Fix the Booster holder on the mounting legs with four M10 bolts 4 Put the rear panel in place 5 Mount the two M M union connections on the flow and the return of the boile...

Страница 8: ...justment 10 Mount a 90 elbow on the lower nipple of the Booster 11 On this elbow mount the 2 tube with the two right hand threads Pay attention to the threads one tube has a left hand thread 12 On thi...

Страница 9: ...nion connexion 19 Connect the shunt pump with its upper and lower tube between the HeatMaster and the Booster 20 Mount the 6 studs on the flange and put the gasket in place 21 Locate the flue collecto...

Страница 10: ...H 664Y2900 C BOOSTER KIT ASSEMBLY 24 Hydraulic connexion of the heating system 25 Electric connexion of the shunt pump M5 see pages 4 5 and 6 26 Commissioning of the system and control of the complete...

Отзывы: