37
Installer's Handbook (Evo) - 660Y3000 • A
EN
Pump Configuration 5
Flex 4
ERR
Flex 6
P4
Flex 3
P3
Flex 2
DHW
Flex 1
CH
Flex 5
FL
Error/Flame
CH2
CH1
DHW
CH1/CH2/
DHW
Flame
PRESET CONFIGURATION 5
Warm water
Cold water
Main
Screen
Sub-
screen
item
Sub-item
Required selection
Model
HeatMaster (Pre-set)
Pump Settings
Preset Pump Config
Config. 5
Heating Operation
Enabled ( )
CH2 Circuit
Disabled
Demand
Thermostat and
Setpoint
DHW Operation
Enabled (
)
Demand
Sensor
DHW
CH
Electrical board terminals
Terminal /pins
Used to connect
AC
V M
ax
1
2
3
4
5
6
1
2
3
4
5
6
W
W
W
W
W
W
4
5
6
1
2
3
1
2
3
4
6
X
15
1
2
3
4
5
6
7
8
9
10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X
11
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
17
16
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
W
R
Or
Bk
Bk
Bk
V
Bk
4
2
1
3
2
1
1
2
3
1
2
3
4
5
6
8
9
10
11
12
1
2
3
4
5
13
6
14
7
X2
1
2
3
4
5
6
7
8
9
10
W
R
Y
R
Y
BK
BK
W
6
7
8
9
10
1
2
3
4
5
X3
1
2
3
4
5
6
7
8
9
10
11
12
V
W
R
Bk
7
8
9
10
11
1
2
3
4
5
12
6
X1
R
Bk
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Or
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
V
1
2
3
4
5
1
2
3
4
5
8
Bk
2
3
1
15
12
13
14
X
12
X9
P
14
1
2
3
4
1
2
3
4
5
6
B
V
B
W
P
13
B
Or
1
2
3
Bk
B
Y/Gr
V
Br
B
Br
Br
Y/Gr
B
B
4
5
6
7
8
8
7
6
5
4
1
2
3
5
F0
0
X
10
0
N
L
N
L
V
ON / OFF
3
230 V
~ 50Hz
1
N
L
N
L
N
L
2
6
B
Y/Gr
Br
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
W
B
Br
B
Br
B
Br
Y/Gr
B
X
101
4
X
10
1
2
X20
1624
2
1
1
NTC 5
9
2
1
1
NTC 2
10
2
1
1
NTC 1
11
Br
B
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
1
X103
X103
Harness
code: A10021
14
25
X
18
V
W
B
W
B
B
9
10
11
12
13
14
15
16
16
15
14
13
12
11
10
9
X
10
0
7
Y/Gr
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4
P3
FL
26
1
1
3
3
6
6
4
4
7
7
8
8
9
9
5
5
2
2
5AT Fuse
5AT Fuse
5AT Fuse
PUMP PWM
Br
Br
B
B
B
V
Y/Gr
C
M
1
2
3
1
2
3
27
AC
V M
ax
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
Or
Bk
Bk
Bk
V
Bk
4
2
1
3
2
1
8
9
10
11
12
1
2
3
4
5
13
6
1
2
3
4
5
6
7
8
9
10
W
R
Y
R
Y
BK
BK
W
6
7
8
9
10
1
2
3
4
5
X3
1
2
3
4
5
6
7
8
9
10
11
12
V
W
R
Bk
7
8
9
10
11
1
2
3
4
5
12
6
X1
R
Bk
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Or
Bk
Bk
W
V
1
2
3
4
5
1
2
3
4
5
8
Bk
12
13
14
X
12
X9
P
14
1
2
3
4
1
2
3
4
5
6
B
V
B
W
P
13
B
Or
1
2
3
Bk
B
Y/Gr
V
Br
B
Br
Br
Y/Gr
B
B
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
1
2
3
5
F0
0
X
10
0
N
L
N
L
ON / OFF
3
230 V
~ 50Hz
1
N
L
N
L
N
L
2
6
B
Y/Gr
Br
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
W
B
Y/Gr
Br
Br
B
B
Y/Gr
B
Or
Br
B
Br
Y/Gr
B
X
101
4
X
10
1
2
X20
2
1
1
NTC 5
9
2
1
1
NTC 2
10
2
1
1
NTC 1
11
Br
B
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
1
X103
X103
Harness
code: A10021
14
L
N
230 V
V
W
B
W
B
B
9
10
11
12
13
14
15
16
16
15
14
13
12
11
10
9
X
10
0
7
Y/Gr
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4
P3
FL
26
1
1
3
3
6
6
4
4
7
7
8
8
9
9
5
5
2
2
5AT Fuse
5AT Fuse
5AT Fuse
PUMP PWM
Br
Br
B
B
B
V
Y/Gr
C
M
1
2
3
1
2
3
27
..... Flex 6
(9/ - 10/L - 11/N)
..... Flex 5
(12/L - 13/N)
..... Flex 3
(14/ - 15/L - 16/N)
..... Flex 4
(1/L - 2/N)
..... Flex 2
(3/ - 4/N - 5/L)
--
Flame sensor
CH Pump
Error (Alarm)
DHW pump
ACV Max
1
2
3
4
5
6
1 2 3 4 5 6
W
W
W
W
W
W
4
5
6
1
2
3
1
2
3
4
6
X15
1 2 3 4 5 6 7 8 9 10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X11
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
17
16
3
4
1
2
X16
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
W
R
Or
Bk
Bk
V
Bk
4
2 1
3 2 1
1 2 3
1 2 3 4 5 6
8
9
10 11 12
1
2
3
4
5
13
6
14
7
X2
1 2 3 4 5 6 7 8 9 10
W
R
Y
R
Y
BK
BK
W
6
7
8
9
10
1
2
3
4
5
X3
1 2 3 4 5 6 7 8 9 10 11 12
V
W
R
Bk
7
8
9
10 11
1
2
3
4
5
12
6
X1
R
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Or
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
V
1
2
3
4
5
1 2 3 4 5
8
Bk
2
3
1
15
12
13
14
X12
X9
P14
1
2
3
4
1
2
3
4
5
6
B
V
B
W
P13
B
Or
1
2
3
Bk
B
Y/Gr
W
Br
B
Br
B
F00
W
230 V ~ 50Hz
1
N
L
N
L
N
L
2
B
Y/Gr
Br
B
Y/Gr
Br
Y/Gr
Y/Gr
Y/Gr
X101
19
18
21
20
22
25
X10
1
2
X20
16
26
2 1
1
NTC 5
9
2 1
1
NTC 2
10
2 1
1
NTC 1
11
1
2
3
1
2
1
2
3
4
1
2
3
4
5
6
X7
X4
X6
X5
Bus A
Bus - Ground
Bus B
0-10 Volt - Ground
0-10 Volt - Input
Cascade sensor - Ground
Cascade sensor - Input
NTC 3
NTC 4
1
2
23
24
27
X18
W
B
13 14 15 16
16
15
14
13
X100
7
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
P3
28
230 V
5A
T F
use
5A
T F
use
5A
T F
use
............DHW sensor (NTC3)
............Optional outdoor temp. sensor (NTC4)
............Optional room thermostat 1
............Opt. Aquastat (control of circulator in DHW
circuit)
Installing a three way valve in the heating supply will allow to control the temperature
of the water supply to the heating system. Please contact your ACV representative for
more information.
High temperature heating circuit, possibly with an optional outdoor
temperature sensor and room thermostat, and an additional Domestic
Hot Water tank.
For outdoor sensor characteristics,
refer to
temperature sensors" on page 36
ACVMax Touch settings using the Installer menu
(Installer code needed, see
SYSTEM DIAGRAMS AND SET-UP
Содержание ACVMax Touch
Страница 48: ......