background image

Installation Instructions

RSX LED

©2016 Acuity Brands Lighting, Inc. 
All Rights Reserved. 

Lithonia Lighting Outdoor

One Lithonia Way,  Conyers, GA 30012

Phone: 800-279-8041 Fax: 770-918-1209

www.lithonia.com

         Part  Number: IM-459 Rev A

                  Revision Date: 8/29/19

RSX WBA & WBASC INSTALLATION
Tools Required:
• 9/16" Socket wrench
• 9/64" Allen wrench
• 3/16" Allen wrench
• Flathead Screwdriver (WBASC option only)

CAUTION: APPLY A CONTINUOUS BEAD OF WEATHER – PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO 

ENSURE WEATHER–TIGHT INTEGRITY OF ELECTRICAL COMPONENTS (See Fig 13a or 13b)

1. Place the base plate in orientation shown in Figures 15a (WBASC) and 15b (WBA) and secure to wall with secure base plate 
to wall with (4) 1/4” diameter fasteners (not included with luminaire) using the (4) holes located on the outer corners of the 
base plate. Check the base plate to confirm that it is level and plumb in all directions (See Figure 15b). Note that the WBA and 
WBASC have slightly different mounting patterns for the ¼” bolts.

2. WBASC OPTION ONLY: With the base plate securely fastened to the wall, remove the desired conduit plug(s) from the base 
plate using a flat head screwdriver, feed in supply wires, and attach ¾ NPT conduit pipe.

3. Prepare the cover plate by ensuring the factory-installed, black foam gasket is in place on the backside of the cover plate 
(See Fig 16) NOTE: For the next steps the curved portion of the cover plate should point upwards when mounted to the wall as 
shown in figure 18.

Page #10

Содержание AARP

Страница 1: ...aced Recycle For information on how to recycle LED electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every p...

Страница 2: ...minaire that are not factory wired to the luminaire must be checked for compatibility with the luminaire prior to installation LED fixtures must be powered directly off a switched circuit Unless indiv...

Страница 3: ...s device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference rec...

Страница 4: ...r 8 Lithonia drilling pattern and has 3 holes The top and bottom hole are threaded b The longer bar has one top hole and a slot with a slid ing threaded hole to be used on poles with existing drill pa...

Страница 5: ...second bolt through the arm slot and into the available threaded hole of the mounting bar See Fig 4 5 The luminaire is supplied with a clearance slot in the back to allow wires to be pulled into the...

Страница 6: ...Tools Required 5 8 Socket wrench 3 16 Allen wrench 5 32 Allen wrench Minimum tenon pole diameter 2 schedule 40 pipe 2 3 8 OD 1 Slip luminaire Mast Arm Mount over 2 3 8 pole tenon See Figure 7a 2 Use...

Страница 7: ...e set screws enough to flip the luminaire over as shown below in figure 8a then loosen the six captive screws on door to access the wire connection area Remove the rubber grommet see figure 8b before...

Страница 8: ...ground connection and lock it Repeat this step for black hot and white neutral wires Select matching colored wires coming from SPD See Figure 9a 9b 9c 6 Use cable tie and bundle all newly attached wir...

Страница 9: ...ided 7 16 14 x 4 1 2 bolt through Mast Arm Mount and drilled 1 2 hole on tenon and place provided 7 16 nut onto bolt see figure 12 and tighten securely to 45 50 ft lbs 9 Evenly tighten the Six 6 3 8 1...

Страница 10: ...the splice access cover and pull supply wire leads from knuckle cavity See figures 13a and 13b 2 Slip luminaire knuckle fitter over 2 3 8 pole tenon and evenly tighten the six 6 3 8 16 UNC knuckle ten...

Страница 11: ...oximately 38 ft lbs See figure 14 For units with photocontrol receptacle the fixture mounting aiming angle must be restricted from 0 to 45 from horizontal per ANSI C136 10 2010 7 Energize the luminair...

Страница 12: ...BA and secure to wall with secure base plate to wall with 4 1 4 diameter fasteners not included with luminaire using the 4 holes located on the outer corners of the base plate Check the base plate to...

Страница 13: ...ge components and void warranties 6 Make sure no wires are pinched and tuck excess wire up into the luminaire mounting area and reinstall the SPA Cover that was removed in step 3 Tighten the two cover...

Страница 14: ...is mounted securely to the pole the angle of the luminaire can be safely adjusted 3 If the luminaire angle will be adjusted DO NOT pull the luminaire supply wires taut leaving slack in the input wires...

Страница 15: ...Screwdriver AAWSC only Minimum Square Pole 3 5 Face Minimum Round Pole 3 2 Diameter CAUTION APPLY A CONTINUOUS BEAD OF WEATHER PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO ENSURE WEATHER TI...

Страница 16: ...om set screws to the same length 5 Now alternating between the top and bottom sets of set screws gently tighten until snug If the base plate was installed level approximately 1 threads should be visib...

Страница 17: ...ult setting is maximum output install luminaire as normal 1 Loosen six captive screws and remove RSX door to access the luminaire electronics Fig 23 Set aside for reinstallation 2 In all RSX family lu...

Страница 18: ...lithonia com Part Number IM 459 Rev A Revision Date 8 29 19 3 Make sure that wires and door tethers are not pinched and that the door gasket is still snugly in its groove on the door Re install the mo...

Отзывы: