background image

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.

Failure to follow any of these instructions could void product warranties.  For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands

  

Indoor/Outdoor 

Indoor 

Lighting 

 Outdoor 

Lighting 

 Controls 

 Daylighting 

 

 

  

Lithonia Lighting 

Gotham 

 

 

American Electric Lighting 

DARK TO LIGHT 

SunOptics   

  Carandini 

 Mark 

Architectural 

Lighting 

Antique 

Street 

Lamps 

 LC&D 

  Holophane 

 Peerless 

  Hydrel 

  ROAM 

 

  RELOC    

Renaissance Lighting

 

 Tersen 

  Sensor 

Switch 

  Light 

Concepts 

Winona 

Lighting 

    Synergy

Acuity Brands Lighting, Inc.  assumes no responsibility for claims arising out of improper or careless installation or handling of its products.

ABL LED General Warnings, Form No. 503.203

© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

 

Never connect components under load. 

 

Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire 

insulation. 

 

Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the 

luminaire must be checked for compatibility with the luminaire prior to installation.  LED fixtures must 

be powered directly off a switched circuit. 

 

Unless individual product specifications deem otherwise:  Do not restrict fixture ventilation.  Allow for 

some volume of airspace around fixture.  Avoid covering LED fixtures with insulation, foam, or other 

material that will prevent convection or conduction cooling. 

 

Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient 

temperature.  

 

Only use fixture in its intended location.    

 

LED products are Polarity Sensitive.  Ensure proper Polarity before installation.  

 

Electrostatic Discharge (ESD): ESD can damage LED fixtures.  Personal grounding equipment must be 

worn during all installation or servicing of the unit. 

 

Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter 

performance. 

 

Some components inside the fixture may not be serviceable.  In the unlikely event your unit may 

require service, stop using the unit immediately and contact an ABL representative for assistance.

 

Always read the fixtures complete installation instructions prior to installation for any additional fixture 

specific warnings.    

 

CAUTION:  RISK OF PRODUCT DAMAGE

Содержание AARP

Страница 1: ...aced Recycle For information on how to recycle LED electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every p...

Страница 2: ...minaire that are not factory wired to the luminaire must be checked for compatibility with the luminaire prior to installation LED fixtures must be powered directly off a switched circuit Unless indiv...

Страница 3: ...s device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference rec...

Страница 4: ...r 8 Lithonia drilling pattern and has 3 holes The top and bottom hole are threaded b The longer bar has one top hole and a slot with a slid ing threaded hole to be used on poles with existing drill pa...

Страница 5: ...second bolt through the arm slot and into the available threaded hole of the mounting bar See Fig 4 5 The luminaire is supplied with a clearance slot in the back to allow wires to be pulled into the...

Страница 6: ...Tools Required 5 8 Socket wrench 3 16 Allen wrench 5 32 Allen wrench Minimum tenon pole diameter 2 schedule 40 pipe 2 3 8 OD 1 Slip luminaire Mast Arm Mount over 2 3 8 pole tenon See Figure 7a 2 Use...

Страница 7: ...e set screws enough to flip the luminaire over as shown below in figure 8a then loosen the six captive screws on door to access the wire connection area Remove the rubber grommet see figure 8b before...

Страница 8: ...ground connection and lock it Repeat this step for black hot and white neutral wires Select matching colored wires coming from SPD See Figure 9a 9b 9c 6 Use cable tie and bundle all newly attached wir...

Страница 9: ...ided 7 16 14 x 4 1 2 bolt through Mast Arm Mount and drilled 1 2 hole on tenon and place provided 7 16 nut onto bolt see figure 12 and tighten securely to 45 50 ft lbs 9 Evenly tighten the Six 6 3 8 1...

Страница 10: ...the splice access cover and pull supply wire leads from knuckle cavity See figures 13a and 13b 2 Slip luminaire knuckle fitter over 2 3 8 pole tenon and evenly tighten the six 6 3 8 16 UNC knuckle ten...

Страница 11: ...oximately 38 ft lbs See figure 14 For units with photocontrol receptacle the fixture mounting aiming angle must be restricted from 0 to 45 from horizontal per ANSI C136 10 2010 7 Energize the luminair...

Страница 12: ...BA and secure to wall with secure base plate to wall with 4 1 4 diameter fasteners not included with luminaire using the 4 holes located on the outer corners of the base plate Check the base plate to...

Страница 13: ...ge components and void warranties 6 Make sure no wires are pinched and tuck excess wire up into the luminaire mounting area and reinstall the SPA Cover that was removed in step 3 Tighten the two cover...

Страница 14: ...is mounted securely to the pole the angle of the luminaire can be safely adjusted 3 If the luminaire angle will be adjusted DO NOT pull the luminaire supply wires taut leaving slack in the input wires...

Страница 15: ...Screwdriver AAWSC only Minimum Square Pole 3 5 Face Minimum Round Pole 3 2 Diameter CAUTION APPLY A CONTINUOUS BEAD OF WEATHER PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO ENSURE WEATHER TI...

Страница 16: ...om set screws to the same length 5 Now alternating between the top and bottom sets of set screws gently tighten until snug If the base plate was installed level approximately 1 threads should be visib...

Страница 17: ...ult setting is maximum output install luminaire as normal 1 Loosen six captive screws and remove RSX door to access the luminaire electronics Fig 23 Set aside for reinstallation 2 In all RSX family lu...

Страница 18: ...lithonia com Part Number IM 459 Rev A Revision Date 8 29 19 3 Make sure that wires and door tethers are not pinched and that the door gasket is still snugly in its groove on the door Re install the mo...

Отзывы: